User guide

Span Your Valves
Chapter 9
9-15
Span your clamp close velocity (flow) valve(s) for optimum velocity
performance. Do this in three parts:
Confirm critical values
Span your clamp close velocity (flow) valve(s)
Test valve linearity with a velocity vs. position profile
Important: You may omit the procedure Span your clamp close velocity
(flow) valve(s) if the recorded valve spanning data from the manufacturer for
velocity control limits FCC45-48, SCC45-48, and TCC45-45 (chapter 7) are
adequate for your application.
Confirm Critical Values
Important: Confirm that your entries for configuration values (chapter 7)
and profile values (chapter 8) for clamp close profiles are as follows:
On Worksheet: Confirm Your Configuration: With These Words or Bits: ProSet Addr.
7A, 7B, 7C QDC module output to which you connected
your selected velocity control valve
FCC02B02,B01,B00 = your selection
SCC02B02,B01,B00 = your
selection
TCC02B02,B01,B00 = your selection
B37/18, 17, 16
B37/82, 81, 80
B37/146,145,144
Your unselected setoutput values for outputs
14
FCC0912 = your value
SCC0912 = your value
TCC0912 = your value
N43:58
N43:6568
N43:125128
All ramping is disabled with zero ramp rates FCC1720 = FCC2528 = 0
SCC1720 = SCC2528 = 0
TCC1720 = TCC2528 = 0
N43:1316 N43:2124
N43:7376 N43:8184
N43:133136 N43:141144
Velocity limits:
Minimum Control Limit
Maximum Control Limit
Selected Velocity Valve, Output for Min
Selected Velocity Valve, Output for Max
FCC45=SCC45=TCC45=0
FCC46=SCC46=TCC46=sys vel
FCC47=SCC47=TCC47=your value
FCC48=SCC48=TCC48=your value
N43:41, 101, 161
N43:42, 102, 162
N43:43, 103, 163
N43:44, 104, 164
8A Selected inches/second as velocity units CPC03B14 = 1 B37/302
Mold protection CPC03B11 = 0 B37/299
Logical bridge CPC03B10 = B09 = B08 = 0 B37/298, 297, 296
Expert Response Compensation (ERC) = Off CPC04B15 = B13B08 = 1 B37/319, 317312
Openloop control CPC04B07 = B05B00 = 1 B37/311, 309304
Endof Segment position setpoints CPC11,14,17 N43:247, 250, 253
Start LPC position CPC61 N43:297
Mold Safe Position CPC62 N43:298
If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.
FCC, SCC, TCC Profiles -