User guide

Span Your Valves
Chapter 9
9-3
Profile Not UsedOpen LoopClosed LoopVelocityPressure
SOC
TOC
OSC
EAC
ERC
If necessary, review system pressure, hydraulic circuits and corresponding
control options presented in chapter 2 under the sections System Pressure
and Example Hydraulic Circuits, to verify that your application is
hydraulically correct.
The following table lists worksheets containing initial values from chapters
7 and 8 that you will use in this chapter.
Data Block: Worksheet:
Clamp Low Pressure Close Configuration Block (LPC) 7B
Clamp Close Configuration Blocks (FCC, SCC, TCC) 7A
Clamp Close Profile Block (CPC) 8A
Injection Configuration Block (INC) 7C
Injection Profile Block (IPC) 8B
Pack Configuration Block (PKC) 7D
Hold Configuration Block (HDC) 7E
Pack/Hold Profile Block (HPC) 8C
Plastication Configuration Block (PLC) 7F
Plastication Profile Block (PPC) 8D
Clamp Open and Open Slow Configuration Blocks
(FOC, SOC, TOC, OSC)
7G
Clamp Open Profile Block (OPC) 8E
Ejector Configuratiion Blocks (EAC, ERC) 7H
Ejector Profile Block (EPC) 8F
ATTENTION: As with any machine start-up, install a test
mold. Programming errors, configuration errors, or hydraulic
problems could lead to personal injury and/or machine damage.
ATTENTION: Make sure all machine guards and shields are in
place before proceeding to guard against personal injury.
Referenced
W
orksheets