Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-19
Worksheet 7H
(continued)
Clamp Open Slow (OSC) Configuration Block
Control Word ProSet 600 Addr. Value Description Units
OSC05 N43:481 1000
Minimum ERC PercentageVelocity
Percent
8
OSC06 N43:482 1000
Minimum ERC PercentagePressure
Percent
8
OSC08 N43:484 0 Profile Watchdog Timer Preset Time
1
OSC09 N43:485 * Output #1 SetOutput Value during Profile Percent Signal Output
4
OSC10 N43:486 * Output #2 SetOutput Value during Profile Percent Signal Output
4
OSC11 N43:487 * Output #3 SetOutput Value during Profile Percent Signal Output
4
OSC12 N43:488 * Output #4 SetOutput Value during Profile Percent Signal Output
4
OSC17 N43:493 0 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC18 N43:494 0 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC19 N43:495 0 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC20 N43:496 0 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC25 N43:501 0 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC26 N43:502 0 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC27 N43:503 0 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC28 N43:504 0 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC33 N43:509 * Output #1 SetOutput Value at Endof Profile Percent Signal Output
4
OSC34 N43:510 * Output #2 SetOutput Value at Endof Profile Percent Signal Output
4
OSC35 N43:511 * Output #3 SetOutput Value at Endof Profile Percent Signal Output
4
OSC36 N43:512 * Output #4 SetOutput Value at Endof Profile Percent Signal Output
4
OSC41 N43:517 0 Pressure Minimum Control Limit Pressure
3
OSC42 N43:518 System Pressure Pressure Maximum Control Limit Pressure
3
OSC43 N43:519 * Selected Pressure Valve Output for Minimum Percent Signal Output
4
OSC44 N43:520 * Selected Pressure Valve Output for Maximum Percent Signal Output
4
OSC45 N43:521 0 Velocity Minimum Control Limit Velocity along Axis
2
OSC46 N43:522 Max Velocity per
OEM specs*
Velocity Maximum Control Limit Velocity along Axis
2
OSC47 N43:523 * Selected Velocity Valve Output for Minimum Percent Signal Output
4
OSC48 N43:524 * Selected Velocity Valve Output for Maximum Percent Signal Output
4
OSC49 N43:525 100 Proportional Gain for Pressure Control None
OSC50 N43:526 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
OSC51 N43:527 0 Derivative Gain for Pressure Control Time (Algorithm)
7
Time
1
OSC52 N43:528 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
OSC53 N43:529 0 Feed Forward Gain for Velocity Control None
OSC57 N43:533 0 Profile High Pressure Alarm Setpoint Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Millimeters per Sec
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
00.00 to 99.99 Seconds
*Refer to the appropriate section later in this chapter for information on this parameter