Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-17
Worksheet 7G
(continued)
Third Clamp Open (TOC) Configuration Block
Control Word ProSet 600 Addr. Value Description Units
TOC05 N43:421 1000
Minimum ERC PercentageVelocity
Percent
8
TOC06 N43:422 1000
Minimum ERC PercentagePressure
Percent
8
TOC08 N43:424 0 Profile Watchdog Timer Preset Time
1
TOC09 N43:425 * Output #1 SetOutput Value during Profile Percent Signal Output
3
TOC10 N43:426 * Output #2 SetOutput Value during Profile Percent Signal Output
3
TOC11 N43:427 * Output #3 SetOutput Value during Profile Percent Signal Output
3
TOC12 N43:428 * Output #4 SetOutput Value during Profile Percent Signal Output
3
TOC17 N43:433 0 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC18 N43:434 0 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC19 N43:435 0 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC20 N43:436 0 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC25 N43:441 0 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC26 N43:442 0 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC27 N43:443 0 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC28 N43:444 0 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC33 N43:449 * Output #1 SetOutput Value at Endof Profile Percent Signal Output
3
TOC34 N43:450 * Output #2 SetOutput Value at Endof Profile Percent Signal Output
3
TOC35 N43:451 * Output #3 SetOutput Value at Endof Profile Percent Signal Output
3
TOC36 N43:452 * Output #4 SetOutput Value at Endof Profile Percent Signal Output
3
TOC41 N43:457 0 Pressure Minimum Control Limit Pressure
2
TOC42 N43:458 System Pressure Pressure Maximum Control Limit Pressure
2
TOC43 N43:459 * Selected Pressure Valve Output for Minimum Percent Signal Output
3
TOC44 N43:460 * Selected Pressure Valve Output for Maximum Percent Signal Output
3
TOC45 N43:461 0 Velocity Minimum Control Limit Velocity along Axis
5
TOC46 N43:462 Max Velocity per
OEM specs*
Velocity Maximum Control Limit Velocity along Axis
5
TOC47 N43:463 * Selected Velocity Valve Output for Minimum Percent Signal Output
3
TOC48 N43:464 * Selected Velocity Valve Output for Maximum Percent Signal Output
3
TOC49 N43:465 100 Proportional Gain for Pressure Control None
TOC50 N43:466 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
TOC51 N43:467 0 Derivative Gain for Pressure Control Time (Algorithm)
7
Time
1
TOC52 N43:468 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
TOC53 N43:469 0 Feed Forward Gain for Velocity Control None
TOC57 N43:473 0 Profile High Pressure Alarm Setpoint Pressure
2
1
Time
2
Pressure
3
Percent
Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds 0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
5
Velocity along Axis
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
00.00 to 99.99 Inches per Second 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
000.0 to 999.9 Millimeters per Sec 00.00 to 99.99 Seconds
*Refer to the appropriate section later in this chapter for information on this parameter