Chapter 7
7-15
Worksheet 7F
(continued)
Second Clamp Open (SOC) Configuration Block
Control Word ProSet 600 Addr. Value Description Units
SOC05 N43:361 1000
Minimum ERC PercentageVelocity
Percent
8
SOC06 N43:362 1000
Minimum ERC PercentagePressure
Percent
8
SOC08 N43:364 0 Profile Watchdog Timer Preset Time
1
SOC09 N43:365 * Output #1 SetOutput Value during Profile Percent Signal Output
3
SOC10 N43:366 * Output #2 SetOutput Value during Profile Percent Signal Output
3
SOC11 N43:367 * Output #3 SetOutput Value during Profile Percent Signal Output
3
SOC12 N43:368 * Output #4 SetOutput Value during Profile Percent Signal Output
3
SOC17 N43:373 0 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC18 N43:374 0 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC19 N43:375 0 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC20 N43:376 0 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC25 N43:381 0 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC26 N43:382 0 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC27 N43:383 0 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC28 N43:384 0 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC33 N43:389 * Output #1 SetOutput Value at Endof Profile Percent Signal Output
3
SOC34 N43:390 * Output #2 SetOutput Value at Endof Profile Percent Signal Output
3
SOC35 N43:391 * Output #3 SetOutput Value at Endof Profile Percent Signal Output
3
SOC36 N43:392 * Output #4 SetOutput Value at Endof Profile Percent Signal Output
3
SOC41 N43:397 0 Pressure Minimum Control Limit Pressure
2
SOC42 N43:398 System Pressure Pressure Maximum Control Limit Pressure
2
SOC43 N43:399 * Selected Pressure Valve Output for Minimum Percent Signal Output
3
SOC44 N43:400 * Selected Pressure Valve Output for Maximum Percent Signal Output
3
SOC45 N43:401 0 Velocity Minimum Control Limit Velocity along Axis
5
SOC46 N43:402 Max Velocity per
OEM specs*
Velocity Maximum Control Limit Velocity along Axis
5
SOC47 N43:403 * Selected Velocity Valve Output for Minimum Percent Signal Output
3
SOC48 N43:404 * Selected Velocity Valve Output for Maximum Percent Signal Output
3
SOC49 N43:405 100 Proportional Gain for Pressure Control None
SOC50 N43:406 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
SOC51 N43:407 0 Derivative Gain for Pressure Control Time (Algorithm)
7
Time
1
SOC52 N43:408 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
SOC53 N43:409 0 Feed Forward Gain for Velocity Control None
SOC57 N43:413 0 Profile High Pressure Alarm Setpoint Pressure
2
1
Time
2
Pressure
3
Percent
Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds 0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
5
Velocity along Axis
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
00.00 to 99.99 Inches per Second 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
000.0 to 999.9 Millimeters per Sec 00.00 to 99.99 Seconds
*Refer to the appropriate section later in this chapter for information on this parameter