First Clamp Open (FOC) Configuration Block
Control Word ProSet 600 Addr. Value Description Units
FOC05 N43:301 1000
Minimum ERC PercentageVelocity
Percent
8
FOC06 N43:302 1000
Minimum ERC PercentagePressure
Percent
8
FOC08 N43:304 0 Profile Watchdog Timer Preset Time
1
FOC09 N43:305 * Output #1 SetOutput Value during Profile Percent Signal Output
4
FOC10 N43:306 * Output #2 SetOutput Value during Profile Percent Signal Output
4
FOC11 N43:307 * Output #3 SetOutput Value during Profile Percent Signal Output
4
FOC12 N43:308 * Output #4 SetOutput Value during Profile Percent Signal Output
4
FOC17 N43:313 0 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC18 N43:314 0 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC19 N43:315 0 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC20 N43:316 0 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC25 N43:321 0 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC26 N43:322 0 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC27 N43:323 0 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC28 N43:324 0 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
FOC33 N43:329 * Output #1 SetOutput Value at Endof Profile Percent Signal Output
4
FOC34 N43:330 * Output #2 SetOutput Value at Endof Profile Percent Signal Output
4
FOC35 N43:331 * Output #3 SetOutput Value at Endof Profile Percent Signal Output
4
FOC36 N43:332 * Output #4 SetOutput Value at Endof Profile Percent Signal Output
4
FOC41 N43:337 0 Pressure Minimum Control Limit Pressure
3
FOC42 N43:338 System Pressure Pressure Maximum Control Limit Pressure
3
FOC43 N43:339 * Selected Pressure Valve Output for Minimum Percent Signal Output
4
FOC44 N43:340 * Selected Pressure Valve Output for Maximum Percent Signal Output
4
FOC45 N43:341 0 Velocity Minimum Control Limit Velocity along Axis
2
FOC46 N43:342 Max Speed per
OEM specs*
Velocity Maximum Control Limit Velocity along Axis
2
FOC47 N43:343 * Selected Velocity Valve Output for Minimum Percent Signal Output
4
FOC48 N43:344 * Selected Velocity Valve Output for Maximum Percent Signal Output
4
FOC49 N43:345 100 Proportional Gain for Pressure Control None
FOC50 N43:346 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
FOC51 N43:347 0 Derivative Gain for Pressure Control Time (Algorithm)
7
Time
1
FOC52 N43:348 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
FOC53 N43:349 0 Feed Forward Gain for Velocity Control None
FOC57 N43:353 0 Profile High Pressure Alarm Setpoint Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Millimeters per Sec
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
00.00 to 99.99 Seconds
*Refer to the appropriate section later in this chapter for information on this parameter