Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-7
Worksheet 7B
(continued)
Second Clamp Close (SCC) Configuration Block
Control Word ProSet 600 Addr. Value Description Units
SCC05 N43:61 1000
Minimum ERC PercentageVelocity
Percent
8
SCC06 N43:62 1000
Minimum ERC PercentagePressure
Percent
8
SCC08 N43:64 0 Profile Watchdog Timer Preset Time
1
SCC09 N43:65 * Output #1 SetOutput Value during Profile Percent Signal Output
4
SCC10 N43:66 * Output #2 SetOutput Value during Profile Percent Signal Output
4
SCC11 N43:67 * Output #3 SetOutput Value during Profile Percent Signal Output
4
SCC12 N43:68 * Output #4 SetOutput Value during Profile Percent Signal Output
4
SCC17 N43:73 0 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC18 N43:74 0 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC19 N43:75 0 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC20 N43:76 0 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC25 N43:81 0 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC26 N43:82 0 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC27 N43:83 0 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC28 N43:84 0 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
SCC33 N43:89 * Output #1 SetOutput Value at Endof Profile Percent Signal Output
4
SCC34 N43:90 * Output #2 SetOutput Value at Endof Profile Percent Signal Output
4
SCC35 N43:91 * Output #3 SetOutput Value at Endof Profile Percent Signal Output
4
SCC36 N43:92 * Output #4 SetOutput Value at Endof Profile Percent Signal Output
4
SCC41 N43:97 0 Pressure Minimum Control Limit Pressure
3
SCC42 N43:98 System
Pressure
Pressure Maximum Control Limit Pressure
3
SCC43 N43:99 * Selected Pressure Valve Output for Minimum Percent Signal Output
4
SCC44 N43:100 * Selected Pressure Valve Output for Maximum Percent Signal Output
4
SCC45 N43:101 0 Velocity Minimum Control Limit Velocity along Axis
2
SCC46 N43:102 Max Velocity per
OEM specs*
Velocity Maximum Control Limit Velocity along Axis
2
SCC47 N43:103 * Selected Velocity Valve Output for Minimum Percent Signal Output
4
SCC48 N43:104 * Selected Velocity Valve Output for Maximum Percent Signal Output
4
SCC49 N43:105 100 Proportional Gain for Pressure Control None
SCC50 N43:106 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
SCC51 N43:107 0 Derivative Gain for Pressure Control Time (Algorithm)
7
Time
1
SCC52 N43:108 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
SCC53 N43:109 0 Feed Forward Gain for Velocity Control None
SCC57 N43:113 0 Profile High Pressure Alarm Setpoint Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Millimeters per Sec
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
00.00 to 99.99 Seconds
*Refer to the appropriate section later in this chapter for information on this parameter