7
7-1
Load Initial Configuration Values
This chapter describes how to prepare the machine to run clamp and
ejector control profiles. Major topics include how to:
use configuration command block worksheets
set your accel/decel ramp rates
set pressure control limits
set velocity control limits
enter and downloading your worksheet values
This chapter helps you determine and enter values into the clamp and
ejector configuration blocks. The configuration blocks provide the QDC
module with information on how you want to run your clamp and ejectors.
Important: Do not start this chapter until you have:
spanned your sensors, and moved hydraulic cylinders (chapter 3)
jogged the clamp and ejector (chapter 5)
Command and Status Blocks Used
The following table contains a list of command blocks you are to configure
throughout the course of this chapter. You may reference these command
blocks in Sections 1 and 3 of the Plastic Molding Module Reference
Manual (pub. no. 1771-6.5.88). The following table also provides you
with important information for getting ready to run profiles:
Command and Status Blocks
used in this Chapter:
Type: Used in this chapter to: ProSet
600 Files:
First Clamp Close (FCC) Command Enter Configuration Values B37, N43
Second Clamp Close (SCC) Command Enter Configuration Values B37, N43
Third Clamp Close (TCC) Command Enter Configuration Values B37, N43
Low Pressure Close (LPC) Command Enter Configuration Values B37, N43
First Clamp Open (FOC) Command Enter Configuration Values B37, N43
Second Clamp Open (SOC) Command Enter Configuration Values B37, N43
Third Clamp Open (TOC) Command Enter Configuration Values B37, N43
Clamp Open Slow (OSC) Command Enter Configuration Values B37, N43
Ejector Advance (EAC) Command Enter Configuration Values B39, N45
Ejector Retract (ERC) Command Enter Configuration Values B39, N45
System Status (SYS) Status View Programming Errors B35, N41
Chapter
Objectives