Manual
Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-6
Table 6.I
Status
Bits for Clamp and Eject Mode
Category: Bit Status
(when = 1):
QDC Block
Addr.:
ProSet
Addr.:
Jog Status unassigned # 1 jog SYS01B09 B35/09
unassigned # 2 jog SYS01B10 B35/10
unassigned # 3 jog SYS01B11 B35/11
executing clamp forward jog SYS01B12 B35/12
executing clamp reverse jog SYS01B13 B35/13
executing ejector advance jog SYS01B14 B35/14
executing ejector retract jog SYS01B15 B35/15
Profile Complete 1st clamp close profile complete SYS02B00 B35/16
2nd clamp close profile complete SYS02B01 B35/17
3rd clamp close profile complete SYS02B02 B35/18
LP close profile complete SYS02B03 B35/19
1st clamp open profile complete SYS02B10 B35/26
2nd clamp open profile complete SYS02B11 B35/27
3rd clamp open profile complete SYS02B12 B35/28
clamp open slow profile complete SYS02B13 B35/29
ejector profile complete SYS02B14 B35/30
Busy Status no action (outputs at zero) SYS02B15 B35/31
Miscellaneous Status clamp in mold protection zone SYS03B00 B35/32
mold safe SYS03B01 B35/33
tonnage complete SYS03B02 B35/34
clamp in openslow zone SYS03B06 B35/38
mold open SYS03B07 B35/39
ejector stopped at end of stroke SYS03B08 B35/40
mold open dwell timer is timing SYS03B09 B35/41
ejector forward dwell timer is timing SYS03B10 B35/42
cycle complete SYS03B11 B35/43
ejector fully advanced SYS03B12 B35/44
ejector beyond tip advance position SYS03B13 B35/45
ejector inside tip retract position SYS03B14 B35/46
ejector fully retracted SYS03B15 B35/47