Manual
Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-4
Table 6.E
Command
Bits to Interrupt Clamp Movement Between Profiles
Bit Description: QDC Block Addr.:
0 = start 2nd clamp close profile @ endof 1st
1 = stop and setoutput @ endof 1st
CPC03B08
0 = start 3rd clamp close profile @ endof 2nd
1 = stop and setoutput @ end of 2nd
CPC03B09
0 = start LP close profile @ endof 3rd
1 = stop and setoutput @ endof 3rd
CPC03B10
0 = start 2nd clamp open profile @ endof 1st
1 = stop and setoutput @ endof 1st
OPC03B08
0 = start 3rd clamp open profile @ endof 2nd
1 = stop and setoutput @ endof 2nd
OPC03B09
0 = start clamp open slow profile @ endof 3rd
1 = stop and setoutput @ endof 3rd
OPC03B10
Table 6.F
Miscellaneous
Status Bits to T
rigger New Clamp Events
Reason for Using: Bit Description: QDC Block
Addr.:
To drop pump adders, or shift solenoids Clamp in moldprotect zone SYS03B00
To add pump adders, or shift solenoids for
tonnage build or lockup
Mold safe SYS03B01
To start inject cycle Tonnage complete SYS03B02
To drop pump adders, or shift solenoids Clamp in openslow zone SYS03B06
To idle the machine until starting next action Mold fully open SYS03B07
To prevent starting next cycle when machine is
in auto mode
Opendwell timer is timing SYS03B09
To start next cycle with machine in auto mode Cycle complete SYS03B11
To reopen the clamp when the part is stuck LP close watchdog timeout SYS04B03