Manual

Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-4
Table 6.E
Command
Bits to Interrupt Clamp Movement Between Profiles
Bit Description: QDC Block Addr.:
0 = start 2nd clamp close profile @ endof 1st
1 = stop and setoutput @ endof 1st
CPC03B08
0 = start 3rd clamp close profile @ endof 2nd
1 = stop and setoutput @ end of 2nd
CPC03B09
0 = start LP close profile @ endof 3rd
1 = stop and setoutput @ endof 3rd
CPC03B10
0 = start 2nd clamp open profile @ endof 1st
1 = stop and setoutput @ endof 1st
OPC03B08
0 = start 3rd clamp open profile @ endof 2nd
1 = stop and setoutput @ endof 2nd
OPC03B09
0 = start clamp open slow profile @ endof 3rd
1 = stop and setoutput @ endof 3rd
OPC03B10
Table 6.F
Miscellaneous
Status Bits to T
rigger New Clamp Events
Reason for Using: Bit Description: QDC Block
Addr.:
To drop pump adders, or shift solenoids Clamp in moldprotect zone SYS03B00
To add pump adders, or shift solenoids for
tonnage build or lockup
Mold safe SYS03B01
To start inject cycle Tonnage complete SYS03B02
To drop pump adders, or shift solenoids Clamp in openslow zone SYS03B06
To idle the machine until starting next action Mold fully open SYS03B07
To prevent starting next cycle when machine is
in auto mode
Opendwell timer is timing SYS03B09
To start next cycle with machine in auto mode Cycle complete SYS03B11
To reopen the clamp when the part is stuck LP close watchdog timeout SYS04B03