Manual
Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-3
Table 6.C
Command
Bits for Automatic Functions in Clamp and Eject Mode
To initiate this
profile/movement:
Toggle this bit: Or the profile/movement
starts automatically after:
If this bit is
Reset:
1st Clamp Close DYC02B00 - -
2nd Clamp Close DYC02B01 1st Clamp Close CPC03B08
3rd Clamp Close DYC02B02 2nd Clamp Close CPC03B09
Low Pressure Close DYC02B03 3rd Clamp Close CPC03B10
1st Clamp Open DYC02B10 - -
2nd Clamp Open DYC02B11 1st Clamp Open OPC03B08
3rd Clamp Open DYC02B12 2nd Clamp Open OPC03B09
Clamp Open Slow DYC02B13 3rd Clamp Open OPC03B10
First Ejector
Advance
DYC02B14 On Clamp Position During
Open
EPC03B08 and
EPC03B09
Ejector Continue DYC03B15 Previous Ejector Stroke EPC03B12
Table 6.D
Status
and Command Bit Interaction for Automatic Functions
in Clamp and Eject Mode
For this
Profile/Movement:
During Execution
this bit is:
At Completion
this bit is:
At completion
If this Then this
command bit is: status bit is:
SET RESET SET RESET also SET also SET
1st Clamp Close SYS21B00 SYS02B00 SYS02B00 SYS21B00 CPC03B08 SYS22B00
2nd Clamp Close SYS21B01 SYS02B01 SYS02B01 SYS21B01 CPC03B09 SYS22B01
3rd Clamp Close SYS21B02 SYS02B02 SYS02B02 SYS21B02 CPC03B10 SYS22B02
Low Pressure Close SYS21B03 SYS02B03 SYS02B03 SYS21B03 --- SYS22B03
1st Clamp Open SYS21B10 SYS02B10 SYS02B10 SYS21B10 OPC03B08 SYS22B10
2nd Clamp Open SYS21B11 SYS02B11 SYS02B11 SYS21B11 OPC03B09 SYS22B11
3rd Clamp Open SYS21B12 SYS02B12 SYS02B12 SYS21B12 OPC03B10 SYS22B12
Clamp Open Slow SYS21B13 SYS02B13 SYS02B13 SYS21B13 --- SYS22B13
Ejector Advance SYS21B14 SYS02B14 SYS21B14 SYS02B14 EPC03B12 SYS22B14
Intermediate Ejector
Retract
SYS21B14 SYS02B14 SYS21B14 SYS02B14 EPC03B12 SYS22B15
Final Ejector Retract SYS21B14 SYS02B14 SYS02B14 SYS21B14 --- SYS22B15