Manual

Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-2
Table 6.A lists the tables included in this chapter along with specific
information found in each:
Table 6.A
Bit
T
able Summary
Type of Function: What the Table Contains: How You Implement Commands:
Table 6.B Manual (nonprofiled) Command and status bits to control and monitor
manual jog, direct setoutput, and stop
To enable: set command bit (0 to 1)
To terminate: reset command bit (1 to 0)
Table 6.C Automatic (profiled) Command bits to control profiles To enable: toggle command bit (0 to 1 to 0).
Terminated by the QDC module automatically.
To force early termination: set stop bit (0 to 1),
or initiate another automatic function.
Table 6.D Automatic (profiled) Status and command bits to link automatic
functions during a machine cycle
Input conditions and permissives to initiate
subsequent machine movements:
(1 = enabled, 0 = disabled)
Table 6.E Automatic (profiled) Command bits to interrupt clamp movement see table
Table 6.F Automatic (profiled) Miscellaneous status bits to trigger clamp action 0 = disabled, 1 = enabled
Table 6.G Automatic (profiled) Command bits to enable/disable ejector profiles see table
Table 6.H Automatic (profiled) Miscellaneous status bits to trigger ejector
action
0 = disabled, 1 = enabled
Table 6.I --- Status bits for clamp and eject mode see table
Table 6.J --- Command bits for clamp and eject mode see table
Table 6.B
Command
and Status Bits for Manual Control in Clamp and Eject Mode
To Initiate this action: Set this bit: The QDC module sets this
bit during execution:
Unassigned # 1 Jog DYC01B09 SYS01B09
Unassigned # 2 Jog DYC01B10 SYS01B010
Unassigned # 3 Jog DYC01B11 SYS01B11
Clamp Forward Jog DYC01B12 SYS01B12
Clamp Reverse Jog DYC01B13 SYS01B13
Ejector Advance Jog DYC01B14 SYS01B14
Ejector Retract Jog DYC01B15 SYS01B15
Direct Setoutput DYC01B08 SYS01B08
Stop DYC02B15 SYS02B15
Use Bit Tables