Manual
Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-2
Table 6.A lists the tables included in this chapter along with specific
information found in each:
Table 6.A
Bit
T
able Summary
Type of Function: What the Table Contains: How You Implement Commands:
Table 6.B Manual (nonprofiled) Command and status bits to control and monitor
manual jog, direct setoutput, and stop
To enable: set command bit (0 to 1)
To terminate: reset command bit (1 to 0)
Table 6.C Automatic (profiled) Command bits to control profiles To enable: toggle command bit (0 to 1 to 0).
Terminated by the QDC module automatically.
To force early termination: set stop bit (0 to 1),
or initiate another automatic function.
Table 6.D Automatic (profiled) Status and command bits to link automatic
functions during a machine cycle
Input conditions and permissives to initiate
subsequent machine movements:
(1 = enabled, 0 = disabled)
Table 6.E Automatic (profiled) Command bits to interrupt clamp movement see table
Table 6.F Automatic (profiled) Miscellaneous status bits to trigger clamp action 0 = disabled, 1 = enabled
Table 6.G Automatic (profiled) Command bits to enable/disable ejector profiles see table
Table 6.H Automatic (profiled) Miscellaneous status bits to trigger ejector
action
0 = disabled, 1 = enabled
Table 6.I --- Status bits for clamp and eject mode see table
Table 6.J --- Command bits for clamp and eject mode see table
Table 6.B
Command
and Status Bits for Manual Control in Clamp and Eject Mode
To Initiate this action: Set this bit: The QDC module sets this
bit during execution:
Unassigned # 1 Jog DYC01B09 SYS01B09
Unassigned # 2 Jog DYC01B10 SYS01B010
Unassigned # 3 Jog DYC01B11 SYS01B11
Clamp Forward Jog DYC01B12 SYS01B12
Clamp Reverse Jog DYC01B13 SYS01B13
Ejector Advance Jog DYC01B14 SYS01B14
Ejector Retract Jog DYC01B15 SYS01B15
Direct Setoutput DYC01B08 SYS01B08
Stop DYC02B15 SYS02B15
Use Bit Tables