Manual

Jog Your Machine
Chapter 5
5-4
Word 1 in the Dynamic Command block (DYC01) is used to enable and
disable individual jogs. Word 1 in the System Status block (SYS01) may
also be used to monitor the QDC modules reaction to jog commands.
Below are two quick cross-reference tables identifying the jog enable and
status bits for the clamp and ejector:
Table 5.A
Clamp
and Eject Jog Enable Bits
Command Block Word: ProSet 600 Address: Description:
DYC01B12 B35/396 Execute Clamp Jog Forward
DYC01B13 B35/397 Execute Clamp Jog Reverse
DYC01B14 B35/398 Execute Ejector Jog Advance
DYC01B15 B35/399 Execute Ejector Jog Retract
Table 5.B
Clamp
and Eject Jog Status Bits
Status Block Word: ProSet 600
Address:
Description:
SYS01B12 B35/12 Clamp Jog Forward in Progress
SYS01B13 B35/13 Clamp Jog Reverse in Progress
SYS01B14 B35/14 Ejector Jog Advance in Progress
SYS01B15 B35/15 Ejector Jog Retract in Progress
Take time now to develop ladder logic (independent of Pro-Set 600
software) to jog the clamp and ejector with the QDC module. You need to
monitor switches on your operator control panel, and set corresponding
command bits.
We provide a programming example (Figure 5.1) for jog control for
instructional purposes only. Your application-specific programming may
vary significantly from this example.
Important: You may also need to develop ladder logic that changes the
direction of clamp and ejector travel hydraulically when you command the
QDC module to jog in reverse.
Jog
Y