Configure the QDC Module's
Inputs and Outputs
Chapter 3
3-6
T
able 3.A (continued)
Determining Initial Sensorconfiguration V
alues for W
orksheet 3D
Category: If: Then Use a Value Equal to:
Analog Signal @ Min Pressure your sensors are forwardacting low end of your selected range
(Lines 7 and 15) your sensors are reverseacting high end of your selected range
Analog Signal @ Max Pressure your sensors are forwardacting high end of your selected range
(Lines 8 and 16) your sensors are reverseacting low end of your selected range
Worksheet 3D
Determining
Initial Sensorconfiguration V
alues
Input Control Word ProSet
600 Addr
. Value Description Units
1 MCC37 N41:33 0 Minimum Ejector Position Ejector Axis Measured from zero
1
MCC38 N41:34 Maximum Ejector Position Ejector Axis Measured from zero
1
MCC39 N41:35 Analog Signal @ Min Ejector Position Input Signal Range
2
MCC40 N41:36 Analog Signal @ Max Ejector Position Input Signal Range
2
2 MCC45 N41:41 0 Minimum Ejector Pressure Ejector Pressure
3
MCC46 N41:42 Maximum Ejector Pressure Ejector Pressure
3
MCC47 N41:43 Analog Signal @ Min Ejector Pressure Input Signal Range
2
MCC48 N41:44 Analog Signal @ Max Ejector Pressure Input Signal Range
2
3 MCC23 N41:19 0 Minimum Clamp Position Clamp Axis Measured from zero
1
MCC24 N41:20 Maximum Clamp Position Clamp Axis Measured from zero
1
MCC25 N41:21 Analog Signal @ Min Clamp Position Input Signal Range
2
MCC26 N41.22 Analog Signal @ Max Clamp Position Input Signal Range
2
4 MCC31 N41:27 0 Minimum Clamp Pressure Clamp Pressure
3
MCC32 N41:28 Maximum Clamp Pressure Clamp Pressure
3
MCC33 N41:29 Analog Signal @ Min Clamp Pressure Input Signal Range
2
MCC34 N41:30 Analog Signal @ Max Clamp Pressure Input Signal Range
2
1
Incremental Distance
2
Input
Signal Range
3
Pressure
00.00
to 99.99 Inches
00.00 to 10.00V dc or
0000 to 9999 PSI
000.0 to 999.9 Millimeters
01.00 to 05.00V dc or
000.0 to 999.9 Bar
04.00 to 20.00MADC