Manual

Enter Y
our V
alues Here
Blank Worksheets
Appendix A
A-25
Worksheet 7-I
(continued)
Ejector Advance (EAC) Configuration Block
Control Word ProSet 600 Addr. Value Description Units
EAC05 N45:1
Minimum ERC PercentageVelocity
Percent
8
EAC06 N45:2
Minimum ERC PercentagePressure
Percent
8
EAC08 N45:4 Profile Watchdog Timer Preset Time
1
EAC09 N45:5 Output #1 SetOutput Value during Advance Percent Signal Output
4
EAC10 N45:6 Output #2 SetOutput Value during Advance Percent Signal Output
4
EAC11 N45:7 Output #3 SetOutput Value during Advance Percent Signal Output
4
EAC12 N45:8 Output #4 SetOutput Value during Advance Percent Signal Output
4
EAC17 N45:13 Output #1 Acceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC18 N45:14 Output #2 Acceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC19 N45:15 Output #3 Acceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC20 N45:16 Output #4 Acceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC25 N45:21 Output #1 Deceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC26 N45:22 Output #2 Deceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC27 N45:23 Output #3 Deceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC28 N45:24 Output #4 Deceleration Ramp Rate during Advance Percent Signal Output per Second
5
EAC33 N45:29 Output #1 SetOutput Value at EndofAdvance Percent Signal Output
4
EAC34 N45:30 Output #2 SetOutput Value at EndofAdvance Percent Signal Output
4
EAC35 N45:31 Output #3 SetOutput Value at EndofAdvance Percent Signal Output
4
EAC36 N45:32 Output #4 SetOutput Value at EndofAdvance Percent Signal Output
4
EAC41 N45:37 Pressure Minimum Control Limit Pressure
3
EAC42 N45:38 Pressure Maximum Control Limit Pressure
3
EAC43 N45:39 Selected Pressure Valve Output for Minimum Percent Signal Output
4
EAC44 N45:40 Selected Pressure Valve Output for Maximum Percent Signal Output
4
EAC45 N45:41 Velocity Minimum Control Limit Velocity along Axis
2
EAC46 N45:42 Velocity Maximum Control Limit Velocity along Axis
2
EAC47 N45:43 Selected Velocity Valve Output for Minimum Percent Signal Output
4
EAC48 N45:44 Selected Velocity Valve Output for Maximum Percent Signal Output
4
EAC49 N45:45 Proportional Gain for Pressure Control None
EAC50 N45:46 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
EAC51 N45:47 Derivative Gain for Pressure Control Time (Algorithm)
7
Time
1
EAC52 N45:48 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
EAC53 N45:49 Feed Forward Gain for Velocity Control None
EAC57 N45:53 Profile High Pressure Alarm Setpoint Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Millimeters per Sec
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes 00.00 to 99.99 Minutes
00.00 to 99.99
00.00 to 99.99 Seconds