Manual

Span Your Clamp and Ejector Valves
Chapter 9
9-2
Command and Status Blocks Used
The following table contains a list of command blocks you are to configure
throughout the course of this chapter. You may reference these command
blocks in sections 1 and 3 of the Plastic Molding Module Reference
Manual (pub. no. 1771-6.5.88).
Block: Type: Used in this Chapter to: ProSet 600 Files:
System (SYS) Status View Programming Errors
View Clamp Position
View Ejector Position
B35, N41
Clamp Close Profile (CPC) Command Enter Clamp Close Profile Values B37, N43
Clamp Open Profile (OPC) Command Enter Clamp Open Profile Values B37, N43
Ejector Profile (EPC) Command Enter Ejector Profile Values B39, N45
Dynamic Command Block
(DYC)
Command Initiate Profile Execution B37, N43
First Clamp Close (FCC) Command Enter First Clamp Close Values B37, N43
Second Clamp Close (SCC) Command Enter Second Clamp Close Values B37, N43
Third Clamp Close (TCC) Command Enter Third Clamp Close Values B37, N43
Clamp Low Press Close (LPC) Command Enter Clamp Low Press Close Values B37, N43
First Clamp Open (FOC) Command Enter First Clamp Open Values B37, N43
Second Clamp Open (SOC) Command Enter Second Clamp Open Values B37, N43
Third Clamp Open (TOC) Command Enter Third Clamp Open Values B37, N43
Clamp Open Slow (OSC) Command Enter Clamp Open Slow Values B37, N43
Ejector Advance (EAC) Command Enter Ejector Advance Values B39, N45
Ejector Retract (ERC) Command Enter Ejector Retract Values B39, N45
ATTENTION: As with any machine start-up, make sure a test
mold is installed in the machine. Programming errors,
configuration errors, or hydraulic problems could lead to
machine damage or injury to personnel.
ATTENTION: Make sure all machine guards and shields are in
place before proceeding.