Load Initial Configuration Values
Chapter 7
7-29
Table 7.A presents unselected valve setpoints you may wish to use,
depending on your machines valve types and the desired profile action.
Table 7.A
Unselected
V
alve Setpoints
If the unselected
valve controls:
And the unselected
valve configuration is:
And during the
profile the valve is:
And you require
during the profile:
Then Enter:
Pressure Unidirectional Direct acting Maximum Pressure 9999
Pressure Unidirectional Direct acting Medium Pressure 7500 to
5000
Pressure Unidirectional Direct acting Low Pressure 5000 to
2500
Pressure Unidirectional Direct acting Minimum Pressure 0
Pressure Unidirectional Reverse acting Maximum Pressure 0
Pressure Unidirectional Reverse acting Medium Pressure 2500 to
5000
Pressure Unidirectional Reverse acting Low Pressure 5000 to
7500
Pressure Unidirectional Reverse acting Minimum Pressure 9999
Flow Unidirectional Direct acting Maximum Flow 9999
Flow Unidirectional Direct acting Medium Flow 7500 to
5000
Flow Unidirectional Direct acting Low Flow 5000 to
2500
Flow Unidirectional Direct acting Minimum Flow 0
Flow Unidirectional Reverse acting Maximum Flow 0
Flow Unidirectional Reverse acting Medium Flow 2500 to
5000
Flow Unidirectional Reverse acting Low Flow 5000 to
7500
Flow Unidirectional Reverse acting Minimum Flow 9999
Flow Bidirectional Direct acting Maximum Flow 9999
Flow Bidirectional Direct acting Medium Flow 8750 to
7500
Flow Bidirectional Direct acting Low Flow 7500 to
6250
Flow Bidirectional Direct acting Minimum Flow 5000
Flow Bidirectional Reverse acting Maximum Flow 0
Flow Bidirectional Reverse acting Medium Flow 1250 to
2500
Flow Bidirectional Reverse acting Low Flow 2500 to
3750
Flow Bidirectional Reverse acting Minimum Flow 5000