Load Initial Configuration Values
Chapter 7
7-17
Worksheet 7G
(continued)
Hold Configuration Block (HDC)
Control Word ProSet 600 Addr. Value Description Units
HDC06 N44:182 1000 Minimum ERC PercentagePressure Percent
8
HDC09 N44:185 * Output #1 Setoutput Value During Profile Percent Signal Output
4
HDC10 N44:186 * Output #2 Setoutput Value During Profile Percent Signal Output
4
HDC11 N44:187 * Output #3 Setoutput Value During Profile Percent Signal Output
4
HDC12 N44:188 * Output #4 Setoutput Value During Profile Percent Signal Output
4
HDC17 N44:193 0 Output #1 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC18 N44:194 0 Output #2 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC19 N44:195 0 Output #3 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC20 N44:196 0 Output #4 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC25 N44:201 0 Output #1 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC26 N44:202 0 Output #2 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC27 N44:203 0 Output #3 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC28 N44:204 0 Output #4 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC33 N44:209 * Output #1 Setoutput Value at Endof Profile Percent Signal Output
4
HDC34 N44:210 * Output #2 Setoutput Value at Endof Profile Percent Signal Output
4
HDC35 N44:211 * Output #3 Setoutput Value at Endof Profile Percent Signal Output
4
HDC36 N44:212 * Output #4 Setoutput Value at Endof Profile Percent Signal Output
4
HDC41 N44:217 0 Pressure Minimum Control Limit Pressure
3
HDC42 N44:218 * Pressure Maximum Control Limit Pressure
3
HDC43 N44:219 * Selected Pressure Valve, Output for Minimum Percent Signal Output
4
HDC44 N44:220 * Selected Pressure Valve, Output for Maximum Percent Signal Output
4
HDC49 N44:225 100 Proportional Gain for Pressure Control None
HDC50 N44:226 400 Integral Gain for Pressure Control Inverse Time (algorithm)
6
HDC51 N44:227 0 Derivative Gain for Pressure Control Time (algorithm)
7
HDC57 N44:233 0 Profile High Pressure Alarm Setpoint Pressure
3
3
Pressure
4
Percent
Signal Output
0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter