User Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-15
Worksheet 7F
(continued)
Pack Configuration Block (PKC)
Control Word ProSet 600 Addr. Value Description Units
PKC06 N44:122 1000 Minimum ERC PercentagePressure Percent
8
PKC09 N44:125 * Output #1 Setoutput Value During Profile Percent Signal Output
4
PKC10 N44:126 * Output #2 Setoutput Value During Profile Percent Signal Output
4
PKC11 N44:127 * Output #3 Setoutput Value During Profile Percent Signal Output
4
PKC12 N44:128 * Output #4 Setoutput Value During Profile Percent Signal Output
4
PKC17 N44:133 0 Output #1 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC18 N44:134 0 Output #2 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC19 N44:135 0 Output #3 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC20 N44:136 0 Output #4 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC25 N44:141 0 Output #1 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC26 N44:142 0 Output #2 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC27 N44:143 0 Output #3 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC28 N44:144 0 Output #4 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PKC41 N44:157 0 Pressure Minimum Control Limit Pressure
3
PKC42 N44:158 * Pressure Maximum Control Limit Pressure
3
PKC43 N44:159 * Selected Pressure Valve, Output for Minimum Percent Signal Output
4
PKC44 N44:160 * Selected Pressure Valve, Output for Maximum Percent Signal Output
4
PKC49 N44:165 100 Proportional Gain for Pressure Control None
PKC50 N44:166 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
PKC51 N44:167 0 Derivative Gain for Pressure Control Time (Algorithm)
7
PKC57 N44:173 0 Profile High Pressure Alarm Setpoint Pressure
3
3
Pressure
4
Percent
Signal Output
0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes (ISA)
00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter