User Manual

Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-13
Worksheet 7E(continued)
Injection Configuration Block (INC)
Control Word ProSet 600 Addr. Value Description Units
INC05 N44:1 1000 Minimum ERC PercentageVelocity Percent
8
INC06 N44:2 1000 Minimum ERC PercentagePressure Percent
8
INC09 N44:5 * Output #1 Setoutput Value During Profile Percent Signal Output
4
INC10 N44:6 * Output #2 Setoutput Value During Profile Percent Signal Output
4
INC11 N44:7 * Output #3 Setoutput Value During Profile Percent Signal Output
4
INC12 N44:8 * Output #4 Setoutput Value During Profile Percent Signal Output
4
INC17 N44:13 0 Output #1 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC18 N44:14 0 Output #2 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC19 N44:15 0 Output #3 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC20 N44:16 0 Output #4 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC25 N44:21 0 Output #1 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC26 N44:22 0 Output #2 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC27 N44:23 0 Output #3 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC28 N44:24 0 Output #4 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC41 N44:37 0 Pressure Minimum Control Limit Pressure
3
INC42 N44:38 * Pressure Maximum Control Limit Pressure
3
INC43 N44:39 * Selected Pressure Valve, Output for Minimum Percent Signal Output
4
INC44 N44:40 * Selected Pressure Valve, Output for Maximum Percent Signal Output
4
INC45 N44:41 0 Velocity Minimum Control Limit Velocity along Axis
2
INC46 N44:42 * Velocity Maximum Control Limit Velocity along Axis
2
INC47 N44:43 * Selected Velocity Valve, Output for Minimum Percent Signal Output
4
INC48 N44:44 * Selected Velocity Valve, Output for Maximum Percent Signal Output
4
INC49 N44:45 100 Proportional Gain for Pressure Control None
INC50 N44:46 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
INC51 N44:47 0 Derivative Gain for Pressure Control Time (Algorithm)
7
INC52 N44:48 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
INC53 N44:49 0 Feed Forward Gain for Velocity Control None
INC57 N44:53 0 Profile High Pressure Alarm Setpoint Pressure
3
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 inches per second
0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 millimeters per second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter