User Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-11
Worksheet 7D
(continued)
Clamp Low Pressure Close Configuration Block (LPC)
Control Word ProSet 600 Addr. Value Description Units
LPC06 N43:182 1000 Minimum ERC PercentagePressure Percent
7
LPC07 N43:183 0 Tonnage Watchdog Timer Preset Time
1
LPC08 N43:184 0 Profile Watchdog Timer Preset Time
1
LPC09 N43:185 * Output #1 SetOutput Value during Profile Percent Signal Output
3
LPC10 N43:186 * Output #2 SetOutput Value during Profile Percent Signal Output
3
LPC11 N43:187 * Output #3 SetOutput Value during Profile Percent Signal Output
3
LPC12 N43:188 * Output #4 SetOutput Value during Profile Percent Signal Output
3
LPC17 N43:193 0 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC18 N43:194 0 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC19 N43:195 0 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC20 N43:196 0 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC25 N43:201 0 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC26 N43:202 0 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC27 N43:203 0 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC28 N43:204 0 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
LPC33 N43:209 * Output #1 SetOutput Value at Endof Profile Percent Signal Output
3
LPC34 N43:210 * Output #2 SetOutput Value at Endof Profile Percent Signal Output
3
LPC35 N43:211 * Output #3 SetOutput Value at Endof Profile Percent Signal Output
3
LPC36 N43:212 * Output #4 SetOutput Value at Endof Profile Percent Signal Output
3
LPC41 N43:217 0 Pressure Minimum Control Limit Pressure
2
LPC42 N43:218 * Pressure Maximum Control Limit Pressure
2
LPC43 N43:219 * Selected Pressure Valve, Output for Minimum Percent Signal Output
3
LPC44 N43:220 * Selected Pressure Valve, Output for Maximum Percent Signal Output
3
LPC49 N43:225 100 Proportional Gain for Pressure Control None
LPC50 N43:226 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
5
LPC51 N43:227 0 Derivative Gain for Pressure Control Time (Algorithm)
6
LPC57 N43:233 0 Profile High Pressure Alarm Setpoint Pressure
2
1
Time
2
Pressure
3
Percent
Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds
0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
5
Inverse T
ime (Algorithm)
6
T
ime (Algorithm)
7
Percent
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter