User Manual

Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-10
Table 6.G
(continued)
Command and Configuration Bits
Operation: Function Enabled
(when = 1):
ProSet
Address:
QDC Block
Addr.:
Logical Bridge set output @ end of 1st clamp close profile
(0 = start 2nd clamp close profile)
B37/296 CPC03B08
set output @ end of 2nd clamp close profile
(0 = start 3rd clamp close profile)
B37/297 CPC03B09
set output @ end of 3rd clamp close profile
(0 = start clamp LP close profile)
B37/298 CPC03B10
set output @ end of hold profile
(0 = start predecompress movement @ end of hold)
B38/296 HPC03B08
set output @ end of predecompress movement
(0 = start plastication profile @ end of predecompress)
B38/297 HPC03B09
set output at end of plastication profile
(0 = start postdecompression at end of plastication)
B38/488 PPC03B08
set output @ end of 1st clamp open profile
(0 = start 2nd clamp open profile)
B37/616 OPC03B08
set output @ end of 2nd clamp open profile
(0 = start 3rd clamp open profile)
B37/617 OPC03B09
set output @ end of 3rd clamp open profile
(0 = start clamp open slow profile)
B37/618 OPC03B10
Configured
Protection from
Clampzone
Overrun
If a clamp close profile overruns the
mold protection zone:
0 = start LPclose profile
1 = stop and zero outputs
B37/299 CPC03B11
If a clamp open profile overruns the
clamp open slow zone
0 = start open slow profile
1 = stop and zero outputs
B37/619 OPC03B11