Table 6.G
Command
and Configuration Bits
Operation: Function Enabled
(when = 1):
ProSet
B34/xx:
QDC Block
Addr.:
Nonprofiled execute setoutput 392 DYC01B08
Action Commands execute ram (screw) forward jog 393 DYC01B09
execute ram (screw) reverse jog 394 DYC01B10
execute unassigned # 3 jog 395 DYC01B11
execute clamp forward jog 396 DYC01B12
execute clamp reverse jog 397 DYC01B13
execute unassigned #6 jog 398 DYC01B14
execute unassigned #7 jog 399 DYC01B15
Stop Command execute all stop (outputs = zero) 415 DYC02B15
Miscellaneous reset tonnage watchdog timer 416 DYC03B00
Commands reset cure timer 417 DYC03B01
reset SYS01B08 424 DYC03B08
reset latched alarms 425 DYC03B09
reset complete bits 426 DYC03B10
Profile Action execute 1st clamp close profile 400 DYC02B00
Commands execute 2nd clamp close profile 401 DYC02B01
execute 3rd clamp close profile 402 DYC02B02
execute LP clamp close profile 403 DYC02B03
execute injection profile 404 DYC02B04
execute pack profile 405 DYC02B05
execute hold profile 406 DYC02B06
execute predecompression movement 407 DYC02B07
execute plastication profile 408 DYC02B08
execute postdecompression movement 409 DYC02B09
execute 1st clamp open profile 410 DYC02B10
execute 2nd clamp open profile 411 DYC02B11
execute 3rd clamp open profile 412 DYC02B12
execute clamp open slow profile 413 DYC02B13