User Manual

Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-7
Table 6.F
(continued)
Status Bits
Category: Bit Status
(when = 1):
ProSet
B34/xx:
QDC Block
Addr.:
Watchdog Status 1st clamp close watchdog timed out 48 SYS04B00
2nd clamp close watchdog timed out 49 SYS04B01
3rd clamp close watchdog timed out 50 SYS04B02
LP close watchdog timed out 51 SYS04B03
predecompress watchdog timed out 55 SYS04B07
plastication watchdog timed out 56 SYS04B08
postdecompress watchdog timed out 57 SYS04B09
1st clamp open watchdog timed out 58 SYS04B10
2nd clamp open watchdog timed out 59 SYS04B11
3rd clamp open watchdog timed out 60 SYS04B12
clamp open slow watchdog timed out 61 SYS04B13
tonnage watchdog timed out 63 SYS04B15
Profile Status executing 1st close profile 320 SYS21B00
executing 2nd close profile 321 SYS21B01
executing 3rd close profile 322 SYS21B02
executing LP close profile 323 SYS21B03
executing injection profile 324 SYS21B04
executing pack profile 325 SYS21B05
executing hold profile 326 SYS21B06
executing predecompress movement 327 SYS21B07
executing plastication profile 328 SYS21B08
executing postdecompress movement 329 SYS21B09
executing 1st clamp open profile 330 SYS21B10
executing 2nd clamp open profile 331 SYS21B11
executing 3rd clamp open profile 332 SYS21B12
executing clamp open slow profile 333 SYS21B13