User Manual

Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-6
Table 6.F
Status
Bits
Category: Bit Status
(when = 1):
ProSet
B34/xx:
QDC Block
Addr.:
Jog Status executing unassigned #1 jog 09 SYS01B09
executing ram (screw) forward jog 10 SYS01B10
executing ram (screw) reverse jog 11 SYS01B11
executing clamp forward jog 12 SYS01B12
executing clamp reverse jog 13 SYS01B13
executing unassigned #6 jog 14 SYS01B14
executing unassigned #7 jog 15 SYS01B15
Profile Complete 1st clamp close profile complete 16 SYS02B00
2nd clamp close profile complete 17 SYS02B01
3rd clamp close profile complete 18 SYS02B02
LP close profile complete 19 SYS02B03
injection profile complete 20 SYS02B04
pack profile complete 21 SYS02B05
hold profile complete 22 SYS02B06
predecompress movement complete 23 SYS02B07
plastication profile complete 24 SYS02B08
postdecompress movement complete 25 SYS02B09
1st clamp open profile complete 26 SYS02B10
2nd clamp open profile complete 27 SYS02B11
3rd clamp open profile complete 28 SYS02B12
clamp open slow profile complete 29 SYS02B13
Busy Status no action (outputs at zero) 31 SYS02B15
Miscellaneous Status clamp in mold protection zone 32 SYS03B00
mold safe 33 SYS03B01
tonnage complete 34 SYS03B02
cure timer timing 35 SYS03B03
ram (screw) retracted 36 SYS03B04
cure time complete 37 SYS03B05
clamp in openslow zone 38 SYS03B06
mold open 39 SYS03B07
mold opendwell timer is timing 41 SYS03B09
cycle complete 43 SYS03B11