User Manual
Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-5
Table 6.E
Miscellaneous
Status Bits T
o T
rigger New Inject and Clamp Action
Reason for Using: Bit Description: QDC Block
Addr.:
To drop pump adders, or shift solenoids before
starting pack/hold profile
Injection complete SYS02B04
To inhibit clamp from opening in auto mode Cure timer timing SYS03B03
To start clampopen phase Ram (screw) retracted, and
Cure time complete
SYS03B04,
and
SYS03B05
To idle the machine and activate an alarm
because the hopper is running out of plastic
Watchdog for plastication
phase
SYS04B08
To shift solenoids for predecompression Setoutput in progress @ end
of hold
SYS22B06
To shift solenoids for plastication Setoutput in progress @ end
of predecompression
SYS22B07
To shift solenoids for postdecompression Setoutput in progress @ end
of plastication
SYS22B08
To idle the machine until starting next action Setoutput in progress @ end
of postdecompression
SYS22B09
To drop pump adders, or shift solenoids Clamp in moldprotect zone SYS03B00
To add pump adders, or shift solenoids for
tonnage build or lockup
Mold safe SYS03B01
To start inject cycle Tonnage complete SYS03B02
To drop pump adders, or shift solenoids Clamp in openslow zone SYS03B06
To idle the machine until starting next action Mold fully open SYS03B07
To prevent starting next cycle when machine is
in auto mode
Opendwell timer is timing SYS03B09
To start next cycle with machine in auto mode Cycle complete SYS03B11
To reopen the clamp when the part is stuck LP close watchdog timeout SYS04B03