User Manual

Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-3
Table 6.C
Status
and Command Bit Interaction for Automatic Functions
For this
Profile/Movement:
During Execution
this bit in B34 is:
At Completion
this bit in B34 is:
At completion
If this Then this
command bit is: status bit is:
SET RESET SET RESET also SET also SET
1st Clamp Close SYS21B00 SYS02B00 SYS02B00 SYS21B00 CPC03B08 SYS22B00
2nd Clamp Close SYS21B01 SYS02B01 SYS02B01 SYS21B01 CPC03B09 SYS22B01
3rd Clamp Close SYS21B02 SYS02B02 SYS02B02 SYS21B02 CPC03B10 SYS22B02
Low Pressure Close SYS21B03 SYS02B03 SYS02B03 SYS21B03 --- SYS22B03
Injection SYS21B04 SYS02B04 SYS02B04 SYS21B04 --- ---
Pack SYS21B05 SYS02B05 SYS02B05 SYS21B05 --- ---
Hold SYS21B06 SYS02B06 SYS02B06 SYS21B06 HPC03B08 SYS22B06
Predecompression SYS21B07 SYS02B07 SYS02B07 SYS21B07 HPC03B09 SYS22B07
Plastication SYS21B08 SYS02B08 SYS02B08 SYS21B08 PPC03B08 SYS22B08
Postdecompression SYS21B09 SYS02B09 SYS02B09 SYS21B09 --- SYS22B09
1st Clamp Open SYS21B10 SYS02B10 SYS02B10 SYS21B10 OPC03B08 SYS22B10
2nd Clamp Open SYS21B11 SYS02B11 SYS02B11 SYS21B11 OPC03B09 SYS22B11
3rd Clamp Open SYS21B12 SYS02B12 SYS02B12 SYS21B12 OPC03B10 SYS22B12
Clamp Open Slow SYS21B13 SYS02B13 SYS02B13 SYS21B13 --- SYS22B13