User Manual

Enter
Y
our SWTL Configuration Values Here
Configure the QDC Module's I/O
Chapter 3
3-15
Configure the QDC module for SWTL as follows:
1. Determine these SWTL values for ram (screw) and/or clamp travel
with respect to the range of physical travel.
SWTL deadband
Maximum SWTL
Minimum SWTL
2. Record non-zero SWTL values on Worksheet 3-F. Zero values
disable the corresponding SWTLs.
ATTENTION: Leaving your SWTL settings at zero (MCC13,
14, 27, and 28) inhibits the QDC module from performing this
safety function.
Worksheet 3F
SWTL
Configuration V
alues
Control Word ProSet 600 Addr. Value Description Units
MCC13 N40:9 Screw Minimum SWTL Screw Axis Measured from zero
1
MCC14 N40:10 Screw Maximum SWTL Screw Axis Measured from zero
1
MCC15 N40:11 10 Screw SWTL Deadband As noted
1
MCC27 N40:23 Clamp Minimum SWTL Clamp Axis Measured from zero
1
MCC28 N40:24 Clamp Maximum SWTL Clamp Axis Measured from zero
1
MCC29 N40:25 10 Clamp SWTL Deadband As noted
1
1
Incremental Distance
00.00 to 99.99 Inches
000.0 to 999.9 Millimeters
You may now download your adjusted values to the QDC module using
the MCC download procedure presented earlier in this chapter.