User Manual

Enter
Y
our Final V
alues Here
Configure the QDC Module's I/O
Chapter 3
3-9
Worksheet 3E
Final Sensorconfiguration V
alues
Input Line Control Word ProSet 600 Addr. Value Description Units
1 1 MCC09 N40:5 0 Minimum Screw Position Screw Axis Measured from zero
1
2 MCC10 N40:6 Maximum Screw Position Screw Axis Measured from zero
1
3 MCC11 N40:7 Analog Signal @ Min Screw Position Input Signal Range
2
4 MCC12 N40:8 Analog Signal @ Max Screw Position Input Signal Range
2
2 5 MCC17 N40:13 0 Minimum Screw Pressure Screw Pressure
3
6 MCC18 N40:14 Maximum Screw Pressure Screw Pressure
3
7 MCC19 N40:15 Analog Signal @ Min Screw Pressure Input Signal Range
2
8 MCC20 N40:16 Analog Signal @ Max Screw Pressure Input Signal Range
2
3 9 MCC23 N40:19 0 Minimum Clamp Position Clamp Axis Measured from zero
1
10 MCC24 N40:20 Maximum Clamp Position Clamp Axis Measured from zero
1
11 MCC25 N40:21 Analog Signal @ Min Clamp Position Input Signal Range
2
12 MCC26 N40:22 Analog Signal @ Max Clamp Position Input Signal Range
2
4 13 MCC31 N40:27 0 Minimum Clamp Pressure Clamp Pressure
3
14 MCC32 N40:28 Maximum Clamp Pressure Clamp Pressure
3
15 MCC33 N40:29 Analog Signal @ Min Clamp Pressure Input Signal Range
2
16 MCC34 N40:30 Analog Signal @ Max Clamp Pressure Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00
to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC
Determine Values for Ram (Screw) Position Sensor
ATTENTION: Incorrect values entered in DYC09-12 may
result in rapid ram (screw) motion and potential damage to your
barrel and seals of your injection cylinder.
To complete the configuration for your ram (screw) position sensor, do the
following and enter the results on Worksheet 3-E:
Important: If your position sensor has zero and span potentiometers for
setting the zero reference and linear resolution, set them in this procedure.
1. Move the ram (screw) forward until it reaches its mechanical stop at
the nozzle end. This is the zero position.
2. Remove ram (screw) pressure and/or flow to stop movement.