User Manual
Enter
Y
our Initial Values Here
Configure the QDC Module's I/O
Chapter 3
3-5
Worksheet 3D
Determine Initial Sensorconfiguration V
alues
Input Line Control Word ProSet
600 Addr
. Value Description Units
1 1 MCC09 N40:5 0 Minimum Screw Position Screw Axis Measured from zero
1
2 MCC10 N40:6 Maximum Screw Position Screw Axis Measured from zero
1
3 MCC11 N40:7 Analog Signal @ Min Screw Position Input Signal Range
2
4 MCC12 N40:8 Analog Signal @ Max Screw Position Input Signal Range
2
2 5 MCC17 N40:13 0 Minimum Screw Pressure Screw Pressure
3
6 MCC18 N40:14 Maximum Screw Pressure Screw Pressure
3
7 MCC19 N40:15 Analog Signal @ Min Screw Pressure Input Signal Range
2
8 MCC20 N40:16 Analog Signal @ Max Screw Pressure Input Signal Range
2
3 9 MCC23 N40:19 0 Minimum Clamp Position Clamp Axis Measured from zero
1
10 MCC24 N40:20 Maximum Clamp Position Clamp Axis Measured from zero
1
11 MCC25 N40:21 Analog Signal @ Min Clamp Position Input Signal Range
2
12 MCC26 N40.22 Analog Signal @ Max Clamp Position Input Signal Range
2
4 13 MCC31 N40:27 0 Minimum Clamp Pressure Clamp Pressure
3
14 MCC32 N40:28 Maximum Clamp Pressure Clamp Pressure
3
15 MCC33 N40:29 Analog Signal @ Min Clamp Pressure Input Signal Range
2
16 MCC34 N40:30 Analog Signal @ Max Clamp Pressure Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00
to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC
Use this download procedure now and later in this chapter. The procedure
requires you to complete the following general steps:
enter MCC values into the PLC-5 data table
download them to the QDC module (PLC-5 processor in run mode)
correct any data entry (programming) errors
Next we describe the general steps:
Enter MCC Values into Your PLC5 Data Table
With your programming terminal, enter values from Worksheet 3-A thru
Worksheet 3-D into your PLC-5 data table as follows:
1. Switch the PLC-5 processor to program mode.
2. Display your PLC-5 data table.
3. Locate the data file for storing the MCC block. PLC-5 data table
word addresses are listed on the worksheets.
Download MCC Values
to the QDC Module