User Manual
Configure the QDC Module's I/O
Chapter 3
3-4
Table 3.A
Determine
Initial Sensorconfiguration V
alues for W
orksheet 3D
Category: If your: Then Use a Value Equal to:
Minimum Position
(Lines 1 and 9)
N/A zero
Maximum Position
(Lines 2 and 10)
ram
(screw) is fully extended to the
mold end (ram bottom), and the
mold closed position is zero.
maximum range value specified by the
manufacturer (full travel of the sensor
Analog Signal @ Min Position sensor is forwardacting low end of your selected range
(Lines 3 and 11) sensor is reverseacting high end of your selected range
Analog Signal @ Max Position sensor is forwardacting high end of your selected range
(Lines 4 and 12) sensor is reverseacting low end of your selected range
Minimum Pressure
(Lines 5 and 13)
N/A minimum range value specified by the
manufacturer
Maximum Pressure
(Lines 6 and 14)
N/A maximum range value specified by
manufacturer
Analog Signal @ Min Pressure sensors are forwardacting low end of your selected range
(Lines 7 and 15) sensors are reverseacting high end of your selected range
Analog Signal @ Max Pressure sensors are forwardacting high end of your selected range
(Lines 8 and 16) sensors are reverseacting low end of your selected range