User Manual
Enter Y
our V
alues Here
Blank Worksheets
Appendix A
A-29
W
orksheet 7L (continued)
Clamp Open Slow Configuration Block (OSC)
Control Word ProSet 600 Addr. Value Description Units
OSC05 N43:481 Minimum ERC PercentageVelocity Percent
8
OSC06 N43:482 Minimum ERC PercentagePressure Percent
8
OSC08 N43:484 Profile Watchdog Timer Preset Time
1
OSC09 N43:485 Output #1 SetOutput Value during Profile Percent Signal Output
4
OSC10 N43:486 Output #2 SetOutput Value during Profile Percent Signal Output
4
OSC11 N43:487 Output #3 SetOutput Value during Profile Percent Signal Output
4
OSC12 N43:488 Output #4 SetOutput Value during Profile Percent Signal Output
4
OSC17 N43:493 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC18 N43:494 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC19 N43:495 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC20 N43:496 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC25 N43:501 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC26 N43:502 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC27 N43:503 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC28 N43:504 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
5
OSC33 N43:509 Output #1 SetOutput Value at Endof Profile Percent Signal Output
4
OSC34 N43:510 Output #2 SetOutput Value at Endof Profile Percent Signal Output
4
OSC35 N43:511 Output #3 SetOutput Value at Endof Profile Percent Signal Output
4
OSC36 N43:512 Output #4 SetOutput Value at Endof Profile Percent Signal Output
4
OSC41 N43:517 Pressure Minimum Control Limit Pressure
3
OSC42 N43:518 Pressure Maximum Control Limit Pressure
3
OSC43 N43:519 Selected Pressure Valve, Output for Minimum Percent Signal Output
4
OSC44 N43:520 Selected Pressure Valve, Output for Maximum Percent Signal Output
4
OSC45 N43:521 Velocity Minimum Control Limit Velocity along Axis
2
OSC46 N43:522 Velocity Maximum Control Limit Velocity along Axis
2
OSC47 N43:523 Selected Velocity Valve, Output for Minimum Percent Signal Output
4
OSC48 N43:524 Selected Velocity Valve, Output for Maximum Percent Signal Output
4
OSC49 N43:525 Proportional Gain for Pressure Control None
OSC50 N43:526 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
OSC51 N43:527 Derivative Gain for Pressure Control Time (Algorithm)
7
OSC52 N43:528 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
OSC53 N43:529 Feed Forward Gain for Velocity Control None
OSC57 N43:533 Profile High Pressure Alarm Setpoint Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Millimeters per Second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter