User Manual
Enter Y
our V
alues Here
Blank Worksheets
Appendix A
A-27
W
orksheet 7K (continued)
Third Clamp Open Configuration Block (T
OC)
Control Word ProSet 600 Addr. Value Description Units
TOC05 N43:421 Minimum ERC PercentageVelocity Percent
8
TOC06 N43:422 Minimum ERC PercentagePressure Percent
8
TOC08 N43:424 Profile Watchdog Timer Preset Time
1
TOC09 N43:425 Output #1 SetOutput Value during Profile Percent Signal Output
3
TOC10 N43:426 Output #2 SetOutput Value during Profile Percent Signal Output
3
TOC11 N43:427 Output #3 SetOutput Value during Profile Percent Signal Output
3
TOC12 N43:428 Output #4 SetOutput Value during Profile Percent Signal Output
3
TOC17 N43:433 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC18 N43:434 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC19 N43:435 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC20 N43:436 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC25 N43:441 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC26 N43:442 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC27 N43:443 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC28 N43:444 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
TOC33 N43:449 Output #1 SetOutput Value at Endof Profile Percent Signal Output
3
TOC34 N43:450 Output #2 SetOutput Value at Endof Profile Percent Signal Output
3
TOC35 N43:451 Output #3 SetOutput Value at Endof Profile Percent Signal Output
3
TOC36 N43:452 Output #4 SetOutput Value at Endof Profile Percent Signal Output
3
TOC41 N43:457 Pressure Minimum Control Limit Pressure
2
TOC42 N43:458 Pressure Maximum Control Limit Pressure
2
TOC43 N43:459 Selected Pressure Valve, Output for Minimum Percent Signal Output
3
TOC44 N43:460 Selected Pressure Valve, Output for Maximum Percent Signal Output
3
TOC45 N43:461 Velocity Minimum Control Limit Velocity along Axis
5
TOC46 N43:462 Velocity Maximum Control Limit Velocity along Axis
5
TOC47 N43:463 Selected Velocity Valve, Output for Minimum Percent Signal Output
3
TOC48 N43:464 Selected Velocity Valve, Output for Maximum Percent Signal Output
3
TOC49 N43:465 Proportional Gain for Pressure Control None
TOC50 N43:466 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
TOC51 N43:467 Derivative Gain for Pressure Control Time (Algorithm)
7
TOC52 N43:468 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
TOC53 N43:469 Feed Forward Gain for Velocity Control None
TOC57 N43:473 Profile High Pressure Alarm Setpoint Pressure
2
1
Time
2
Pressure
3
Percent
Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds 0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
5
Velocity along Axis
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
00.00 to 99.99 Inches per Second
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
000.0 to 999.9 Millimeters per Second
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter