Appendix A
A-25
W
orksheet 7J (continued)
Second Clamp Open Configuration Block (SOC)
Control Word ProSet 600 Addr. Value Description Units
SOC05 N43:361 Minimum ERC PercentageVelocity Percent
8
SOC06 N43:362 Minimum ERC PercentagePressure Percent
8
SOC08 N43:364 Profile Watchdog Timer Preset Time
1
SOC09 N43:365 Output #1 SetOutput Value during Profile Percent Signal Output
3
SOC10 N43:366 Output #2 SetOutput Value during Profile Percent Signal Output
3
SOC11 N43:367 Output #3 SetOutput Value during Profile Percent Signal Output
3
SOC12 N43:368 Output #4 SetOutput Value during Profile Percent Signal Output
3
SOC17 N43:373 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC18 N43:374 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC19 N43:375 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC20 N43:376 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC25 N43:381 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC26 N43:382 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC27 N43:383 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC28 N43:384 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC33 N43:389 Output #1 SetOutput Value at Endof Profile Percent Signal Output
3
SOC34 N43:390 Output #2 SetOutput Value at Endof Profile Percent Signal Output
3
SOC35 N43:391 Output #3 SetOutput Value at Endof Profile Percent Signal Output
3
SOC36 N43:392 Output #4 SetOutput Value at Endof Profile Percent Signal Output
3
SOC41 N43:397 Pressure Minimum Control Limit Pressure
2
SOC42 N43:398 Pressure Maximum Control Limit Pressure
2
SOC43 N43:399 Selected Pressure Valve, Output for Minimum Percent Signal Output
3
SOC44 N43:400 Selected Pressure Valve, Output for Maximum Percent Signal Output
3
SOC45 N43:401 Velocity Minimum Control Limit Velocity along Axis
5
SOC46 N43:402 Velocity Maximum Control Limit Velocity along Axis
5
SOC47 N43:403 Selected Velocity Valve, Output for Minimum Percent Signal Output
3
SOC48 N43:404 Selected Velocity Valve, Output for Maximum Percent Signal Output
3
SOC49 N43:405 Proportional Gain for Pressure Control None
SOC50 N43:406 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
SOC51 N43:407 Derivative Gain for Pressure Control Time (Algorithm)
7
SOC52 N43:408 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
SOC53 N43:409 Feed Forward Gain for Velocity Control None
SOC57 N43:413 Profile High Pressure Alarm Setpoint Pressure
2
1
Time
2
Pressure
3
Percent
Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds 0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
5
Velocity along Axis
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
00.00 to 99.99 Inches per Second
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
000.0 to 999.9 Millimeters per Second
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter