Enter Y
our V
alues Here
Blank Worksheets
Appendix A
A-19
W
orksheet 7G (continued)
Hold Configuration Block (HDC)
Control Word ProSet 600 Addr. Value Description Units
HDC06 N44:182 Minimum ERC PercentagePressure Percent
8
HDC09 N44:185 Output #1 Setoutput Value During Profile Percent Signal Output
4
HDC10 N44:186 Output #2 Setoutput Value During Profile Percent Signal Output
4
HDC11 N44:187 Output #3 Setoutput Value During Profile Percent Signal Output
4
HDC12 N44:188 Output #4 Setoutput Value During Profile Percent Signal Output
4
HDC17 N44:193 Output #1 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC18 N44:194 Output #2 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC19 N44:195 Output #3 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC20 N44:196 Output #4 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC25 N44:201 Output #1 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC26 N44:202 Output #2 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC27 N44:203 Output #3 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC28 N44:204 Output #4 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
HDC33 N44:209 Output #1 Setoutput Value at Endof Profile Percent Signal Output
4
HDC34 N44:210 Output #2 Setoutput Value at Endof Profile Percent Signal Output
4
HDC35 N44:211 Output #3 Setoutput Value at Endof Profile Percent Signal Output
4
HDC36 N44:212 Output #4 Setoutput Value at Endof Profile Percent Signal Output
4
HDC41 N44:217 Pressure Minimum Control Limit Pressure
3
HDC42 N44:218 Pressure Maximum Control Limit Pressure
3
HDC43 N44:219 Selected Pressure Valve, Output for Minimum Percent Signal Output
4
HDC44 N44:220 Selected Pressure Valve, Output for Maximum Percent Signal Output
4
HDC49 N44:225 Proportional Gain for Pressure Control None
HDC50 N44:226 Integral Gain for Pressure Control Inverse Time (algorithm)
6
HDC51 N44:227 Derivative Gain for Pressure Control Time (algorithm)
7
HDC57 N44:233 Profile High Pressure Alarm Setpoint Pressure
3
3
Pressure
4
Percent
Signal Output
0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter