User Manual

Enter
Y
our Final V
alues Here
Enter Y
our SWTL Configuration Values Here
Blank Worksheets
Appendix A
A-3
W
orksheet 3E
Final Sensorconfiguration V
alues
Input Line Control Word ProSet 600 Addr. Value Description Units
1 1 MCC09 N40:5 Minimum Screw Position Screw Axis Measured from zero
1
2 MCC10 N40:6 Maximum Screw Position Screw Axis Measured from zero
1
3 MCC11 N40:7 Analog Signal @ Min Screw Position Input Signal Range
2
4 MCC12 N40:8 Analog Signal @ Max Screw Position Input Signal Range
2
2 5 MCC17 N40:13 Minimum Screw Pressure Screw Pressure
3
6 MCC18 N40:14 Maximum Screw Pressure Screw Pressure
3
7 MCC19 N40:15 Analog Signal @ Min Screw Pressure Input Signal Range
2
8 MCC20 N40:16 Analog Signal @ Max Screw Pressure Input Signal Range
2
3 9 MCC23 N40:19 Minimum Clamp Position Clamp Axis Measured from zero
1
10 MCC24 N40:20 Maximum Clamp Position Clamp Axis Measured from zero
1
11 MCC25 N40:21 Analog Signal @ Min Clamp Position Input Signal Range
2
12 MCC26 N40:22 Analog Signal @ Max Clamp Position Input Signal Range
2
4 13 MCC31 N40:27 Minimum Clamp Pressure Clamp Pressure
3
14 MCC32 N40:28 Maximum Clamp Pressure Clamp Pressure
3
15 MCC33 N40:29 Analog Signal @ Min Clamp Pressure Input Signal Range
2
16 MCC34 N40:30 Analog Signal @ Max Clamp Pressure Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00
to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC
Worksheet
3F
SWTL Configuration V
alues
Control Word ProSet 600 Addr. Value Description Units
MCC13 N40:9 Screw Minimum SWTL Screw Axis Measured from zero
1
MCC14 N40:10 Screw Maximum SWTL Screw Axis Measured from zero
1
MCC15 N40:11 Screw SWTL Deadband As noted
1
MCC27 N40:23 Clamp Minimum SWTL Clamp Axis Measured from zero
1
MCC28 N40:24 Clamp Maximum SWTL Clamp Axis Measured from zero
1
MCC29 N40:25 Clamp SWTL Deadband As noted
1
1
Incremental Distance
00.00 to 99.99 Inches
000.0 to 999.9 Millimeters