User Manual
Span Your Valves
Chapter 9
9-51
6. Copy final FOC48 (N43:344) into SOC48, TOC48 and OSC48
(N43:404, 464, and 524), and download these changes.
Important: If downloading from your programming terminal, download
FOC, SOC, TOC and/or OSC followed by OPC (chapter 4).
To download: Set B21/
FOC 16
SOC 17
TOC 18
OSC 19
OPC 20
What You Have Accomplished
The valve spanning procedure you just completed has defined the:
range of velocity available during any clamp open profile
end-of-range maximum and minimum signal levels for linear control of
the clamp velocity valve in open-loop control:
For this
range limit
When trying to obtain the
velocity in:
The QDC module drives the selected
velocity valve to % output signal in:
Minimum FOC45,SOC45,TOC45,OSC45 FOC47, SOC47, TOC47, and OSC47
Maximum FOC46,SOC46,TOC46,OSC46 FOC48, SOC48, TOC48, and OSC48
Now, for all clamp-open velocity profiles, the QDC module assumes a
linear relationship between clamp velocity and signal output in open loop.