User Manual
Span Your Valves
Chapter 9
9-42
On Worksheet:
Confirm Your Configuration: With These Words or Bits: Proset Addr:
8E Mold Protection - start open slow on overrun OPC03B11 = 0 B37/619
Logical bridge - start next profile OPC03B10 = B09 = B08 = 0 B37/618, 617, 616
Pressure vs. Position control OPC03B06 = 04 = 02 = 00 = 1 B37/614, 612, 610, 608
Expert Response Compensation (ERC) = Off OPC04B15 - B08 = 1 B37/639632
Openloop control OPC04B07 - B00 = 1 B37/631624
FOC segment pressures OPC10, 13, 16 = your values N43:546, 549, 552
FOC endofsegment position setpoints OPC11, 14, 17 = your values N43:547, 550, 553
Start OSC position setpoint OPC61 = your value N43:597
Mold full open position setpoint OPC62 = your value N43:598
If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.
Span Your Clamp Open Pressure Valve(s)
Span your clamp pressure valve for smooth operation at highest desired
clamp open pressure. Do this in the following procedure by finding
optimum values for:
Minimum Pressure Control Limit FOC41, SOC41, TOC41, and OSC41
Maximum Pressure Control Limit FOC42, SOC42, TOC42, and OSC42
Selected Pressure Valve, Output For Minimum
FOC43, SOC43, TOC43, and OSC43
Selected Pressure Valve, Output For Maximum
FOC44, SOC44, TOC44, and OSC44
Important: If your machine hydraulics are identical for all clamp open
and open slow profiles, complete the procedure for first clamp open by
finding values for FOC41-44, and copy them into the other clamp open
profile words SOC41-44, TOC41-44, and OSC41-44 when told.
Otherwise, repeat the procedure as needed.
Important: If PanelView is operational for clamp profiles, use it to:
observe actuals
change and download setpoints
run profiles
Important: We suggest that you read this procedure before starting.
ATTENTION: As with any machine start-up, install a test
mold. Programming errors, configuration errors, or hydraulic
problems could lead to machine damage or injury to personnel.