User Manual
Enter Y
our V
alues Here
Load Initial Profile Values
Chapter 8
8-25
W
orksheet 8D (continued)
Plastication Profile Block (PPC)
Control Word ProSet 600 Addr. Value Description Units
PPC10 N44:426 * Segment 1 Pressure Setpoint Pressure
3
PPC11 N44:427 * Endof Segment 1 Position Setpoint Distance from Moldend
2
PPC12 N44:428 0 Segment 1 Time Setpoint Time
1
PPC14 N44:430 * Segment 2 Pressure Setpoint Pressure
3
PPC15 N44:431 * Endof Segment 2 Position Setpoint Distance from Moldend
2
PPC16 N44:432 0 Segment 2 Time Setpoint Time
1
PPC18 N44:434 * Segment 3 Pressure Setpoint Pressure
3
PPC19 N44:435 * Endof Segment 3 Position Setpoint Distance from Moldend
2
PPC20 N44:436 0 Segment 3 Time Setpoint Time
1
PPC22 N44:438 * Segment 4 Pressure Setpoint Pressure
3
PPC23 N44:439 * Endof Segment 4 Position Setpoint Distance from Moldend
2
PPC24 N44:440 0 Segment 4 Time Setpoint Time
1
PPC26 N44:442 * Segment 5 Pressure Setpoint Pressure
3
PPC27 N44:443 * Endof Segment 5 Position Setpoint Distance from Moldend
2
PPC28 N44:444 0 Segment 5 Time Setpoint Time
1
PPC30 N44:446 * Segment 6 Pressure Setpoint Pressure
3
PPC31 N44:447 * Endof Segment 6 Position Setpoint Distance from Moldend
2
PPC32 N44:448 0 Segment 6 Time Setpoint Time
1
PPC34 N44:450 * Segment 7 Pressure Setpoint Pressure
3
PPC35 N44:451 * Endof Segment 7 Position Setpoint Distance from Moldend
2
PPC36 N44:452 0 Segment 7 Time Setpoint Time
1
PPC38 N44:454 * Segment 8 Pressure Setpoint Pressure
3
PPC39 N44:455 * Endof Segment 8 Position Setpoint Distance from Moldend
2
PPC40 N44:456 0 Segment 8 Time Setpoint Time
1
PPC42 N44:458 * Segment 9 Pressure Setpoint Pressure
3
PPC43 N44:459 * Endof Segment 9 Position Setpoint Distance from Moldend
2
PPC44 N44:460 0 Segment 9 Time Setpoint Time
1
PPC46 N44:462 * Segment 10 Pressure Setpoint Pressure
3
PPC47 N44:463 * Endof Segment 10 Position Setpoint Distance from Moldend
2
PPC48 N44:464 0 Segment 10 Time Setpoint Time
1
PPC50 N44:466 * Segment 11 Pressure Setpoint Pressure
3
PPC52 N44:468 * Profile Pressure Offset Pressure
3
PPC61 N44:477 0 Cushion Size Distance from Moldend
2
PPC62 N44:478 * Shot Size Incremental Distance
4
1
Time
2
Distance from MCC13 (if not zero) or MCC09
3
Pressure
4
Distance
from PPC61
00.00 to 99.99 Seconds 00.00 to 99.99 Inches 0000 to 9999 PSI 00.00 to 99.99 Inches
000.0 to 999.9 Millimeters
000.0 to 999.9 Bar
000.0 to 999.9 Millimeter
*
Refer to the appropriate section later in this chapter for information on this parameter