User Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-23
Worksheet 7J
(continued)
Second Clamp Open Configuration Block (SOC)
Control Word ProSet 600 Addr. Value Description Units
SOC05 N43:361 1000 Minimum ERC PercentageVelocity Percent
8
SOC06 N43:362 1000 Minimum ERC PercentagePressure Percent
8
SOC08 N43:364 0 Profile Watchdog Timer Preset Time
1
SOC09 N43:365 * Output #1 SetOutput Value during Profile Percent Signal Output
3
SOC10 N43:366 * Output #2 SetOutput Value during Profile Percent Signal Output
3
SOC11 N43:367 * Output #3 SetOutput Value during Profile Percent Signal Output
3
SOC12 N43:368 * Output #4 SetOutput Value during Profile Percent Signal Output
3
SOC17 N43:373 0 Output #1 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC18 N43:374 0 Output #2 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC19 N43:375 0 Output #3 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC20 N43:376 0 Output #4 Acceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC25 N43:381 0 Output #1 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC26 N43:382 0 Output #2 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC27 N43:383 0 Output #3 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC28 N43:384 0 Output #4 Deceleration Ramp Rate during Profile Percent Signal Output per Second
4
SOC33 N43:389 * Output #1 SetOutput Value at Endof Profile Percent Signal Output
3
SOC34 N43:390 * Output #2 SetOutput Value at Endof Profile Percent Signal Output
3
SOC35 N43:391 * Output #3 SetOutput Value at Endof Profile Percent Signal Output
3
SOC36 N43:392 * Output #4 SetOutput Value at Endof Profile Percent Signal Output
3
SOC41 N43:397 0 Pressure Minimum Control Limit Pressure
2
SOC42 N43:398 * Pressure Maximum Control Limit Pressure
2
SOC43 N43:399 * Selected Pressure Valve, Output for Minimum Percent Signal Output
3
SOC44 N43:400 * Selected Pressure Valve, Output for Maximum Percent Signal Output
3
SOC45 N43:401 0 Velocity Minimum Control Limit Velocity along Axis
5
SOC46 N43:402 * Velocity Maximum Control Limit Velocity along Axis
5
SOC47 N43:403 * Selected Velocity Valve, Output for Minimum Percent Signal Output
3
SOC48 N43:404 * Selected Velocity Valve, Output for Maximum Percent Signal Output
3
SOC49 N43:405 100 Proportional Gain for Pressure Control None
SOC50 N43:406 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
SOC51 N43:407 0 Derivative Gain for Pressure Control Time (Algorithm)
7
SOC52 N43:408 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
SOC53 N43:409 0 Feed Forward Gain for Velocity Control None
SOC57 N43:413 0 Profile High Pressure Alarm Setpoint Pressure
2
1
Time
2
Pressure
3
Percent
Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds 0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
5
Velocity along Axis
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
00.00 to 99.99 Inches per Second
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
000.0 to 999.9 Millimeters per Second
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter