User Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-19
Worksheet 7H
(continued)
Plastication Configuration Block (PLC)
Control Word ProSet 600 Addr. Value Description Units
PLC06 N44:362 1000 Minimum ERC PercentagePressure Percent
8
PLC08 N44:364 0 Profile Watchdog Timer Preset Time
1
PLC09 N44:365 * Output #1 Setoutput Value During Profile Percent Signal Output
4
PLC10 N44:366 * Output #2 Setoutput Value During Profile Percent Signal Output
4
PLC11 N44:367 * Output #3 Setoutput Value During Profile Percent Signal Output
4
PLC12 N44:368 * Output #4 Setoutput Value During Profile Percent Signal Output
4
PLC17 N44:373 0 Output #1 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC18 N44:374 0 Output #2 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC19 N44:375 0 Output #3 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC20 N44:376 0 Output #4 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC25 N44:381 0 Output #1 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC26 N44:382 0 Output #2 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC27 N44:383 0 Output #3 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC28 N44:384 0 Output #4 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
PLC33 N44:389 * Output #1 Setoutput Value at Endof Profile Percent Signal Output
4
PLC34 N44:390 * Output #2 Setoutput Value at Endof Profile Percent Signal Output
4
PLC35 N44:391 * Output #3 Setoutput Value at Endof Profile Percent Signal Output
4
PLC36 N44:392 * Output #4 Setoutput Value at Endof Profile Percent Signal Output
4
PLC41 N44:397 0 Pressure Minimum Control Limit Pressure
3
PLC42 N44:398 * Pressure Maximum Control Limit Pressure
3
PLC43 N44:399 * Selected Pressure Valve, Output for Minimum Percent Signal Output
4
PLC44 N44:400 * Selected Pressure Valve, Output for Maximum Percent Signal Output
4
PLC49 N44:405 100 Proportional Gain for Pressure Control None
PLC50 N44:406 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
PLC51 N44:407 0 Derivative Gain for Pressure Control Time (Algorithm)
7
PLC57 N44:413 0 Profile High Pressure Alarm Setpoint Pressure
3
1
Time
3
Pressure
4
Percent
Signal Output
00.00 to 99.99 seconds
0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
00.00 to 99.99 Seconds (AB) 00.00 to 99.99 Seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter