Instruction Manual
Algorithm Selection
IPC Block Identifier
00 = Vel/Pos
01 = Vel/Pos (pressure limited)
10 = Press/Pos
11 = Press/Time
Sign of Velocity Offset
0 = Positive
1 = Negative
Velocity Units
0 = Parameters in Percent Velocity"
1 = Parameters in Inches (mm)/Sec
Sign of Pressure Offset
0 = Positive
1 = Negative
0 = Vel/Pos Closed Loop
1 = Open Loop
0 = Vel/Pos (limited) Closed Loop
1 = Open Loop
0 = Press/Pos Closed Loop
1 = Open Loop
0 = Press/Time Closed Loop
1 = Open Loop
0 = ERC On for Vel/Pos
1 = ERC Off
0 = ERC On for Vel/Pos (limited)
1 = ERC Off
0 = ERC On for Press/Pos
1 = ERC Off
0 = ERC On for Press/Time
1 = ERC Off
Code:
Your value
Required initial value
loaded by ProSet 600
0
or 1
Enter Y
our V
alues Here
Load Initial Profile Values
Chapter 8
8-2
Use Worksheet 8-A to enter setpoints for pressure vs. time and velocity vs.
position injection profiles. The valve spanning procedures in chapter 9
require specific values. We have already entered many values for you, and
help you determine other values in the text that follows.
Worksheet 8A
Injection
Profile Command Block (IPC)
Control Word IPC01Bxx
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B38/bit
79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64
Value 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 1
Control W
ord IPC03Bxx
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B38/bit
111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 96
Value 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 1
Control W
ord IPC04Bxx
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B38/bit
127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112
Value 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
Control Word ProSet 600 Addr. Value Description Units
IPC09 N44:65 * Segment 1 Velocity Setpoint Velocity
4
IPC10 N44:66 * Segment 1 Pressure Setpoint Pressure
3
IPC11 N44:67 * Endof Segment 1 Position Setpoint Distance from Moldend
2
IPC12 N44:68 100 Segment 1 Time Setpoint Time
1
IPC13 N44:69 * Segment 2 Velocity Setpoint Velocity
4
IPC14 N44:70 * Segment 2 Pressure Setpoint Pressure
3
Determine and Record
Setpoints
for the Injection Profile (IPC)