Instruction Manual

Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-9
W
orksheet 7C (continued)
Hold Configuration Command Block (HDC)
Control Word ProSet 600 Addr. Value Description Units
HDC05 N44:181 1000 Minimum ERC PercentageCavity Pressure Percent
8
HDC06 N44:182 1000 Minimum ERC PercentageRam (Screw) Pressure Percent
8
HDC09 N44:185 * Output #1 Setoutput Value During Profile Percent Signal Output
4
HDC10 N44:186 * Output #2 Setoutput Value During Profile Percent Signal Output
4
HDC11 N44:187 * Output #3 Setoutput Value During Profile Percent Signal Output
4
HDC12 N44:188 * Output #4 Setoutput Value During Profile Percent Signal Output
4
HDC17 N44:193 0 Output #1 Accel Ramp Rate During Profile Percent Signal Output per Second
5
HDC18 N44:194 0 Output #2 Accel Ramp Rate During Profile Percent Signal Output per Second
5
HDC19 N44:195 0 Output #3 Accel Ramp Rate During Profile Percent Signal Output per Second
5
HDC20 N44:196 0 Output #4 Accel Ramp Rate During Profile Percent Signal Output per Second
5
HDC25 N44:201 0 Output #1 Decel Ramp Rate During Profile Percent Signal Output per Second
5
HDC26 N44:202 0 Output #2 Decel Ramp Rate During Profile Percent Signal Output per Second
5
HDC27 N44:203 0 Output #3 Decel Ramp Rate During Profile Percent Signal Output per Second
5
HDC28 N44:204 0 Output #4 Decel Ramp Rate During Profile Percent Signal Output per Second
5
HDC33 N44:209 * Output #1 Setoutput Value at Endof Profile Percent Signal Output
4
HDC34 N44:210 * Output #2 Setoutput Value at Endof Profile Percent Signal Output
4
HDC35 N44:211 * Output #3 Setoutput Value at Endof Profile Percent Signal Output
4
HDC36 N44:212 * Output #4 Setoutput Value at Endof Profile Percent Signal Output
4
HDC41 N44:217 0 Ram (screw) Pressure Minimum Control Limit Pressure
3
HDC42 N44:218 * Ram (screw) Pressure Maximum Control Limit Pressure
3
HDC43 N44:219 * Selected Ram (screw) Pressure Valve, Output for Minimum Percent Signal Output
4
HDC44 N44:220 * Selected Ram (screw) Pressure Valve, Output for Maximum Percent Signal Output
4
HDC45 N44:221 0 Cavity Pressure Minimum Control Limit Pressure
1
HDC46 N44:222 * Cavity Pressure Maximum Control Limit Pressure
1
HDC47 N44:223 * Selected Cavity Pressure Valve, Output for Minimum Percent Signal Output
4
HDC48 N44:224 * Selected Cavity Pressure Valve, Output for Maximum Percent Signal Output
4
HDC49 N44:225 100 Proportional Gain for Ram (screw) Pressure Control None
HDC50 N44:226 400 Integral Gain for Ram (screw) Pressure Control Inverse Time (algorithm)
6
HDC51 N44:227 0 Derivative Gain for Ram (screw) Pressure Control Time (algorithm)
7
HDC52 N44:228 100 Proportional Gain for Cavity Pressure Control None
HDC53 N44:229 400 Integral Gain for Cavity Pressure Control Inverse Time (algorithm)
6
HDC54 N44:230 0 Derivative Gain for Cavity Pressure Control Time (algorithm)
7
HDC57 N44:233 0 Profile High Ram (screw) Pressure Alarm Setpoint Pressure
3
HDC58 N44:234 0 Profile High Cavity Pressure Alarm Setpoint Pressure
1
1
Pressure
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00000 to 20000 PSI
00.00 to 99.99 inches per second
0000 to 9999 PSI
00.00 to 99.99
0000.0 to 2000.0 Bar
000.0 to 999.9 millimeters per second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 minutes (ISA) 00.00 to 99.99 minutes (ISA)
00.00 to 99.99
00.00 to 99.99 seconds (AB) 00.00 to 99.99 seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter