Instruction Manual
Enter Y
our V
alues Here
Load Initial Configuration Values
Chapter 7
7-7
W
orksheet 7B (continued)
Pack Configuration Command Block (PKC)
Control Word ProSet 600 Addr. Value Description Units
PKC05 N44:121 1000 Minimum ERC PercentageCavity Pressure Percent
8
PKC06 N44:122 1000 Minimum ERC PercentageRam (Screw) Pressure Percent
8
PKC09 N44:125 * Output #1 Setoutput Value During Profile Percent Signal Output
4
PKC10 N44:126 * Output #2 Setoutput Value During Profile Percent Signal Output
4
PKC11 N44:127 * Output #3 Setoutput Value During Profile Percent Signal Output
4
PKC12 N44:128 * Output #4 Setoutput Value During Profile Percent Signal Output
4
PKC17 N44:133 0 Output #1 Accel Ramp Rate During Profile Percent Signal Output per Second
5
PKC18 N44:134 0 Output #2 Accel Ramp Rate During Profile Percent Signal Output per Second
5
PKC19 N44:135 0 Output #3 Accel Ramp Rate During Profile Percent Signal Output per Second
5
PKC20 N44:136 0 Output #4 Accel Ramp Rate During Profile Percent Signal Output per Second
5
PKC25 N44:141 0 Output #1 Decel Ramp Rate During Profile Percent Signal Output per Second
5
PKC26 N44:142 0 Output #2 Decel Ramp Rate During Profile Percent Signal Output per Second
5
PKC27 N44:143 0 Output #3 Decel Ramp Rate During Profile Percent Signal Output per Second
5
PKC28 N44:144 0 Output #4 Decel Ramp Rate During Profile Percent Signal Output per Second
5
PKC41 N44:157 0 Ram (screw) Pressure Minimum Control Limit Pressure
3
PKC42 N44:158 * Ram (screw) Pressure Maximum Control Limit Pressure
3
PKC43 N44:159 * Selected Ram (screw) Pressure Valve, Output for Minimum Percent Signal Output
4
PKC44 N44:160 * Selected Ram (screw) Pressure Valve, Output for Maximum Percent Signal Output
4
PKC45 N44:161 0 Cavity Pressure Minimum Control Limit Pressure
1
PKC46 N44:162 * Cavity Pressure Maximum Control Limit Pressure
1
PKC47 N44:163 * Selected Cavity Pressure Valve, Output for Minimum Percent Signal Output
4
PKC48 N44:164 * Selected Cavity Pressure Valve, Output for Maximum Percent Signal Output
4
PKC49 N44:165 100 Proportional Gain for Ram (screw) Pressure Control None
PKC50 N44:166 400 Integral Gain for Ram (screw) Pressure Control Inverse Time (Algorithm)
6
PKC51 N44:167 0 Derivative Gain for Ram (screw) Pressure Control Time (Algorithm)
7
PKC52 N44:168 100 Proportional Gain for Cavity Pressure Control None
PKC53 N44:169 400 Integral Gain for Cavity Pressure Control Inverse Time (Algorithm)
6
PKC54 N44:170 0 Derivative Gain for Cavity Pressure Control Time (Algorithm)
7
PKC57 N44:173 0 Profile High Ram (screw) Pressure Alarm Setpoint Pressure
3
PKC58 N44:174 0 Profile High Cavity Pressure Alarm Setpoint Pressure
1
1
Pressure
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00000 to 20000 PSI
00.00 to 99.99 inches per second
0000 to 9999 PSI
00.00 to 99.99
0000.0 to 2000.0 Bar
000.0 to 999.9 millimeters per second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 minutes (ISA)
00.00 to 99.99 minutes (ISA)
00.00 to 99.99
00.00 to 99.99 seconds (AB) 00.00 to 99.99 seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter