Instruction Manual

Enter
Y
our Initial Values Here
Jog Your Machine
Chapter 5
5-8
Worksheet 5. B
Clamp & Eject Jog Configuration Values for QDC Module in Inject Mode
Control Block
Word
ProSet 600 Addr. Value Description Units
Clamp, Forward Jog
JGC33 N40:89 Set Output Values Output #1 % Signal Output
1
JGC34 N40:90 Output #2 % Signal Output
1
JGC35 N40:91 Output #3 % Signal Output
1
JGC36 N40:92 Output #4 % Signal Output
1
Clamp, Reverse Jog
JGC41 N40:97 Set Output Values Output #1 % Signal Output
1
JGC42 N40:98 Output #2 % Signal Output
1
JGC43 N40:99 Output #3 % Signal Output
1
JGC44 N40:100 Output #4 % Signal Output
1
Ejector, Advance Jog
JGC49 N40:105 Set Output Values Output #1 % Signal Output
1
JGC50 N40:106 Output #2 % Signal Output
1
JGC51 N40:107 Output #3 % Signal Output
1
JGC52 N40:108 Output #4 % Signal Output
1
Ejector, Retract Jog
JGC57 N40:113 Set Output Values Output #1 % Signal Output
1
JGC58 N40:114 Output #2 % Signal Output
1
JGC59 N40:115 Output #3 % Signal Output
1
JGC60 N40:116 Output #4 % Signal Output
1
1
%
Signal Output
00.00 to 99.99 %