Instruction Manual

Enter Y
our V
alues Here
Blank Worksheets
Appendix A
A-9
W
orksheet 7A (continued)
Injection Configuration Block (INC)
Control Word ProSet 600 Addr. Value Description Units
INC05 N44:1 1000 Minimum ERC PercentageVelocity Percent
8
INC06 N44:2 1000 Minimum ERC PercentagePressure Percent
8
INC09 N44:5 * Output #1 Setoutput Value During Profile Percent Signal Output
4
INC10 N44:6 * Output #2 Setoutput Value During Profile Percent Signal Output
4
INC11 N44:7 * Output #3 Setoutput Value During Profile Percent Signal Output
4
INC12 N44:8 * Output #4 Setoutput Value During Profile Percent Signal Output
4
INC17 N44:13 0 Output #1 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC18 N44:14 0 Output #2 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC19 N44:15 0 Output #3 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC20 N44:16 0 Output #4 Acceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC25 N44:21 0 Output #1 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC26 N44:22 0 Output #2 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC27 N44:23 0 Output #3 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC28 N44:24 0 Output #4 Deceleration Ramp Rate During Profile Percent Signal Output per Second
5
INC41 N44:37 0 Pressure Minimum Control Limit Pressure
3
INC42 N44:38 * Pressure Maximum Control Limit Pressure
3
INC43 N44:39 * Selected Pressure Valve, Output for Minimum Percent Signal Output
4
INC44 N44:40 * Selected Pressure Valve, Output for Maximum Percent Signal Output
4
INC45 N44:41 0 Velocity Minimum Control Limit Velocity along Axis
2
INC46 N44:42 * Velocity Maximum Control Limit Velocity along Axis
2
INC47 N44:43 * Selected Velocity Valve, Output for Minimum Percent Signal Output
4
INC48 N44:44 * Selected Velocity Valve, Output for Maximum Percent Signal Output
4
INC49 N44:45 100 Proportional Gain for Pressure Control None
INC50 N44:46 400 Integral Gain for Pressure Control Inverse Time (Algorithm)
6
INC51 N44:47 0 Derivative Gain for Pressure Control Time (Algorithm)
7
INC52 N44:48 200 Proportional Gain for Velocity Control Inverse Time (Algorithm)
6
INC53 N44:49 0 Feed Forward Gain for Velocity Control None
INC57 N44:53 0 Profile High Ram (screw) Pressure Alarm Setpoint Pressure
3
INC58 N44:54 0 Profile High Cavity Pressure Alarm Setpoint Pressure
1
1
Pressure
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00000 to 20000 PSI
00.00 to 99.99 inches per second
0000 to 9999 PSI
00.00 to 99.99
0000.0 to 2000.0 Bar
000.0 to 999.9 millimeters per second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse T
ime (Algorithm)
7
T
ime (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 minutes (ISA) 00.00 to 99.99 minutes (ISA)
00.00 to 99.99
00.00 to 99.99 seconds (AB) 00.00 to 99.99 seconds (AB)
*
Refer to the appropriate section later in this chapter for information on this parameter