Instruction Manual

Enter
Y
our Initial Values Here
Blank Worksheets
Appendix A
A-3
W
orksheet 3D
Determine Initial Sensorconfiguration V
alues
Input Line Control
Word
ProSet 600
Address
Value Description Units
1 1 MCC09 N40:5 0 Minimum Screw Position Screw Axis Measured from zero
1
2 MCC10 N40:6 Maximum Screw Position Screw Axis Measured from zero
1
3 MCC11 N40:7 Analog Signal @ Min Screw Position Input Signal Range
2
4 MCC12 N40:8 Analog Signal @ Max Screw Position Input Signal Range
2
2 5 MCC17 N40:13 0 Minimum Screw Pressure Screw Pressure
3
6 MCC18 N40:14 Maximum Screw Pressure Screw Pressure
3
7 MCC19 N40:15 Analog Signal @ Min Screw Pressure Input Signal Range
2
8 MCC20 N40:16 Analog Signal @ Max Screw Pressure Input Signal Range
2
3 9 MCC51 N40:47 0 Minimum Screw RPM Rotational Speed
4
10 MCC52 N40:48 Maximum Screw RPM Rotational Speed
4
11 MCC53 N40:49 Analog Signal @ Min Screw RPM Input Signal Range
2
12 MCC54 N40.50 Analog Signal @ Max Screw RPM Input Signal Range
2
4 13 MCC57 N40:53 0 Minimum Cavity Pressure Cavity Pressure
5
14 MCC58 N40:54 Maximum Cavity Pressure Cavity Pressure
5
15 MCC59 N40:55 Analog Signal @ Min Cavity Pressure Input Signal Range
2
16 MCC60 N40:56 Analog Signal @ Max Cavity Pressure Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00
to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC
4
Rotational Speed
5
Pressure
000.0 to 999.9 RPM
00000 to 20,000 PSI
0000.0 to 2000.0 Bar