Instruction Manual

System Operation:
Inject Mode 0 0
Select Units
0 = English
1 = metric
Code:
Your value
Required initial value
loaded by ProSet 600
0
or 1
Select Input 1 (Screw Position) Range
Select Input 2 (Screw Pressure) Range
Select Input 3 (Screw RPM) Range
Select Input 4 (Cavity Pressure) Range
Input Range
0 - 10 vdc 0 0
1 - 5 vdc 0 1
4 - 20 mA 1 0
Not connected 1 1
Code:
Your value
Required initial value
loaded by ProSet 600
0
or 1
Appendix
A
A-1
Blank Worksheets
Workshet
3A
Select Module Parameters
Control W
ord MCC02Bxx
15 14 13 12
11 10
09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B34/bit
543 542 541 540 539 538 537 536 535 534 533 532 531 530 529 528
Value 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0
Example: If you select Inject operation with English units:
MCC02 = 00000000 00001000
Worksheet
3B
Select Input Ranges for your Sensors
Control W
ord MCC03Bxx
15 14 13 12
11 10
09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B34/bit
559 558 557 556 555 554 553 552 551 550 549 548 547 546 545 544
Value 1 1 1 1 1 1 1 1
Example: If you select an input range of 4-20mA for all four inputs,
MCC03 = 11111111 10101010.