Instruction Manual

Span Your Valves
Chapter 9
9-14
On
Worksheet
Confirm Your Configuration With These Words or Bits
for Hold Pressure
ProSet Addr
7C
(chapter 7)
QDC module output to which you connected your
pressure control valve
HDC02B06, B05, B04 B38/212214
Setoutput values for unselected valves HDC0912 = your values N44:185188
All ramping is disabled with zero ramp rates HDC1720 = 0
HDC2528 = 0
N44:193196
N44:201204
Endofprofile Setoutput values HDC3336 for zero output N44:209212
Pressure limits:
Minimum Pressure Control Limit
Maximum Pressure Control Limit
Selected Pressure Valve, Output for Minimum
Selected Pressure Valve, Output for Maximum
HDC41 = 0
HDC42 = system pressure
HDC43 = your value
HDC44 = your value
N44:217
N44:218
N44:219
N44:220
8B
(chapter 8)
Pressure vs Time algorithm
for Pack and Hold
HPC03B02 = B00 = 0
for ram (screw) pressure
B38/288, 290
Logical bridge to stop and set outputs before:
predecompression
plastication
HPC03B08 = 1
HPC03B09 = 1
B38/296
B38/297
Openloop control HPC04B03, B02, B01, B00 = 1 B38/304307
Expert Response Compensation (ERC) is disabled HPC04B11, B10, B09, B08 = 1 B38/312315
Pressure setpoints HPC10,13,16,19,22, 27, 30, 33,
36, 39 all equal full injection
pressure
start @ N44:246
end @ N44:275
Time setpoints HPC11,14,17,20,23, 28, 31, 34,
37, 40 all equal to 1 second
(100)
start @ N44:247
end @ N44:276
If these are not your current values, we suggest that you correct them now
and download them using the download procedure discussed in chapter 4.
Before proceeding, observe these warnings:
ATTENTION: As with any machine start-up, make sure you
installed a test mold in the machine. Programming errors,
configuration errors, or hydraulic problems could lead to
machine damage or injury to personnel.
ATTENTION: Be sure all machine guards and shields are in
place before proceeding.