Manual
Troubleshooting
Chapter 7
711
Restarting the Press
You re-start the press with this procedure:
1. When the “OD” message is displayed, press ESTOP to drop the seal
relays.
Message code “50” is displayed (swingarm power dropout)
2. Press the START button.
3. Press the RESET LATCHED MSG button.
4. Select INCH mode if not already selected.
5. Inch the press to the near-top position.
Types of OD" Diagnostic Message Codes
The “OD” diagnostic message code accompanies the following type of
diagnostic messages.
Type of Message Hex Code
Downstroke 066 067
Upstroke 068 069
Brake or Motion Detector 072 079, 07A
Cam Limit Switch
Near Top Position
Transition to Downstroke
Downstroke
Transition to Near Bottom Zone
Near Bottom Zone
Transition to Upstroke
Upstroke
Transition to Near Top Position
080 085
086 089
08A 08F
090 093
094 099
09A 09D
09E 09F, 0A0 0A3
0A4 0A7
Hardware or Cable 0F1 0F3